文献速递神经外周血管US

SRU颈动脉多普勒速度标准评估NASCET狭窄准确性的Meta分析

Accuracy of the Society of Radiologists in Ultrasound (SRU) Carotid Doppler Velocity Criteria for Grading North American Symptomatic Carotid Endarterectomy Trial (NASCET) Stenosis: A Meta-Analysis.
PubMed 文献 · J Ultrasound Med · 2022-12-17

该Meta分析纳入9项研究,提取PSV、EDV及ICA/CCA比值数据,评估SRU共识提出的6个多普勒速度切点对NASCET法颈内动脉50%和70%狭窄分级的准确性。结果显示PSV切点准确性存在权衡:50%狭窄切点敏感性高而特异性低,70%狭窄切点特异性高而敏感性中等。

要点

  • PSV 125 cm/s诊断50%狭窄敏感性最高达96%,但特异性较低。
  • PSV 230 cm/s诊断70%狭窄特异性最高达86%,敏感性中等。
  • PSV的AUC最高(0.93),EDV的AUC较低(0.86)。

核心结论

  • SRU共识多普勒切点预测ICA狭窄的准确性各异,PSV切点在50%和70%狭窄诊断中存在敏感性/特异性权衡。

研究设计与样本

  • 系统综述与Meta分析,检索337篇文稿后纳入9项研究(1993–2016年),提取1738个分叉数据点用于PSV、1026个用于EDV、775个用于ICA/CCA比值。
  • 采用两级混合效应模型及分层汇总ROC曲线,以动脉造影测量的NASCET狭窄为参考标准。

诊断标准与关键数值

  • PSV 125 cm/s诊断50%狭窄敏感性96%(95%CI:93%, 98%)。
  • PSV 230 cm/s诊断70%狭窄特异性86%(95%CI:71%, 93%)。
  • PSV诊断50%狭窄AUC为0.93(95%CI:0.92, 0.95)。
  • EDV诊断70%狭窄AUC为0.86(95%CI:0.84, 0.88)。

临床应用与阅片要点

  • 解读颈动脉多普勒报告时需注意PSV切点的敏感性/特异性权衡,避免单一阈值误判。
  • 50%狭窄筛查宜关注高敏感性切点,70%狭窄确认宜关注高特异性切点。

局限性

  • 仅纳入9项研究,样本量有限且研究年份跨度大(1993–2016)。
  • 未直接比较6个切点的相对准确性,部分切点数据可能不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The Society of Radiologists in Ultrasound (SRU) consensus panel proposed six Doppler velocity cut points for classifying internal carotid artery (ICA) stenosis of 50% and 70% according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method. Their relative accuracies have not been compared.

MATERIALS AND METHODS: Meta-analysis performed following comprehensive literature review and identification of manuscripts with graphs of individual patient NASCET ICA stenosis measured by arteriography versus ICA peak-systolic velocity (PSV), end-diastolic velocity (EDV) and ICA PSV to common carotid artery (CCA) PSV. True positives, true negatives, false positives, and false negatives were calculated and used in two-level mixed effects models. Hierarchical summary receiver operating characteristic (ROC) curves were generated. Areas under the ROC curves were estimated.

RESULTS: Nine studies performed between 1993 and 2016 were identified after review of 337 manuscripts. There were 1738 bifurcation data points extracted for PSV, 1026 for EDV, and 775 for ICA/CCA ratio. The highest sensitivity was 96% (95% CI: 93%, 98%) for PSV of 125 cm/s (50% stenosis) and highest specificity 86% (95% CI: 71%, 93%) for PSV of 230 cm/s (70% stenosis). Areas under the ROC curves ranged from a high of 0.93 (95% CI: 0.92, 0.95) for PSV (50% stenosis) to a low of 0.86 (95% CI: 0.84, 0.88) for EDV (70% stenosis).

CONCLUSIONS: The SRU consensus Doppler cut points vary in their accuracies for predicting ICA stenosis. The PSV cut points have tradeoffs: high sensitivity/low specificity for 50% stenosis and high specificity/moderate sensitivity for 70% stenosis.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Polak, Alexandrov. Accuracy of the Society of Radiologists in Ultrasound (SRU) Carotid Doppler Velocity Criteria for Grading North American Symptomatic Carotid Endarterectomy Trial (NASCET) Stenosis: A Meta-Analysis. J Ultrasound Med. 2022. PMID: 36527708. doi:10.1002/jum.16150

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。