文献速递外周血管CT

第一代光子计数探测器CT下肢动脉CTA与低kVp能量积分CT的对比评估

Evaluation of run-off computed tomography angiography on a first-generation photon-counting detector CT scanner - Comparison with low-kVp energy-integrating CT.
PubMed 文献 · Eur J Radiol · 2022-12-11

本研究比较了光子计数探测器CT(PCD-CT)与能量积分探测器CT(EID-CT)在下肢动脉CTA中的辐射剂量与图像质量。纳入40例PCD-CT患者并按性别、BMI、身高、年龄匹配EID-CT患者,PCD-CT生成40-120 keV虚拟单能图像。结果显示40-60 keV范围SNR和CNR显著优于EID-CT,主观图像质量与EID-CT无显著差异。

要点

  • 40-60 keV虚拟单能图像SNR和CNR显著高于80 kVp和100 kVp EID-CT。
  • 低keV水平主观图像质量更高,与EID-CT无显著差异。
  • SNR和CNR随keV升高呈负相关,阅片时优先选择低keV重建。

关键影像表现/征象

  • 对腹部、盆腔及下肢13个血管节段半自动测量CT值和噪声。
  • 40-60 keV范围SNR和CNR显著超过EID-CT水平。
  • 低keV水平主观图像质量(血管衰减、血管锐利度、整体图像质量,5分Likert量表)显著更高,与EID-CT无显著差异。

临床应用与阅片要点

  • 下肢动脉CTA阅片优先采用40-60 keV虚拟单能重建以获得更优SNR和CNR。
  • 低keV可提高血管对比,但需注意噪声随keV降低而增加,SNR/CNR与keV呈负相关。
  • 主观图像质量与EID-CT相当,低keV重建可替代常规kVp采集用于下肢动脉评估。

局限性

  • 单中心研究,样本量40例PCD-CT与40例EID-CT。
  • EID-CT为回顾性匹配队列。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the overall imaging performance (radiation dose and image quality) of a photon-counting detector CT (PCD-CT) in comparison with a state-of-the-art energy-integrating detector CT (EID-CT) in run-off CTAs.

METHODS: Consecutive patients who underwent run-off CTA on a PCD-CT were included (PCD-CT cohort). A retrospective cohort of patients who had undergone run-off CTA on an EID-CT was matched for gender, body mass index, height, and age (EID-CT cohort). Virtual monoenergetic imaging (VMI) reconstructions for various keV settings (40-120 keV) were generated. CT values and noise were semiautomatically measured for 13 vascular segments of the abdomen, pelvis, and lower extremities. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for each segment. Subjective image quality was evaluated by two radiologists along the dimensions 'vessel attenuation', 'vessel sharpness', and 'overall image quality' using 5-point Likert scales.

RESULTS: Forty patients (age 70.9 ± 9.8 years; 14 women) were included in the PCD-CT cohort and matched with a corresponding number of EID-CT patients. Overall, there was an inverse correlation of signal and noise but also of SNR and CNR with keV levels used for VMI reconstructions. SNR and CNR in the 40 - 60 keV range exceeded EID-CT levels significantly. Subjective image quality was substantially higher at lower keV levels and showed no significant difference to EID-CT.

CONCLUSION: Low keV VMI reconstructions of run-off CTA scans on a PCD-CT result in substantially higher SNR and CNR than 80 kVp and 100 kVp EID-CT acquisitions with equal subjective image quality.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Rippel, Decker, Wudy, et al. Evaluation of run-off computed tomography angiography on a first-generation photon-counting detector CT scanner - Comparison with low-kVp energy-integrating CT. Eur J Radiol. 2022. PMID: 36525704. doi:10.1016/j.ejrad.2022.110645

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。