时间分辨率对CT特征追踪应变测量的影响
结果表明重建增量显著影响应变值,5%增量产生更大的绝对应变值,且高心率或心功能受损时差异减小;平均心率是不确定 demarcation 的独立风险因素。建议控制心率并采用窄R-R重建增量以量化时相性左房应变。
要点
- 窄R-R重建增量(5%)较10%增量产生更大的绝对应变值,左室径向应变差异最大。
- 高心率(>80 bpm)或心功能受损时,重建增量对应变值的影响减弱。
- 平均心率是不确定左房导管与收缩期分界的主要风险因素,与LVEF无关。
核心结论
- R-R间期重建增量是左室和左房CT特征追踪应变值变异的重要来源,尤其在低心率和心功能保留时。
- 为量化时相性左房应变,必须控制心率并采用窄R-R重建增量。
研究设计与样本
- CCTA图像以5%和10%步长在0-100% R-R间期重建,计算左室整体纵向、圆周、径向应变及左房整体纵向应变、射血分数和左房室耦联指数。
- 评估两组重建增量间连续变量的一致性、变异性、左房导管与收缩期分界及20例随机参与者的观察者可重复性。
诊断标准与关键数值
- 左室整体径向应变在5%与10% R-R增量组间差异最大。
- 5% R-R增量组左房导管与收缩期明确分界的出现率显著高于10%组。
- 平均心率为不明确分界的强风险因素,独立于左室射血分数,随平均心率增加不明确分界发生率升高。
- 观察者可重复性独立于R-R重建增量。
临床应用与阅片要点
- 日常CT特征追踪应变测量中应优先采用窄R-R重建增量(如5%)以获取更大绝对应变值。
- 注意高心率患者中重建增量对应变值影响减弱,但分界不明确风险增加,需谨慎判读左房时相。
- 报告应变值时需说明重建增量,因不同增量间应变值存在显著差异。
局限性
- 回顾性研究设计。
- 单中心样本。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Temporal resolution significantly affects strain values demonstrated by Magnetic resonance feature-tracking and speckle-tracking echocardiography. We investigated the influence of R-R interval reconstruction increments on left ventricular (LV) and left atrial (LA) strain measurements of Computed tomography feature-tracking (CT-FT).
METHODS: Subjects who underwent retrospective electrocardiogram-gated coronary CT angiography (CCTA) were retrospectively included, and CCTA images were reconstructed in 5% and 10% steps throughout the entire cardiac cycle (0-100% R-R interval). LV global longitudinal strain (GLS), circumferential strain (GCS), radial strain (GRS), LA GLS, ejection fraction (EF), and left atrioventricular coupling indices were computed. We evaluated the consistency and variability of continuous variables between the two reconstruction increment groups, the demarcation between the LA conduit and contraction phases, and observer reproducibility in 20 randomly selected participants.
RESULTS: Eighty-one participants with or without cardiac disease were included. The reconstruction increment of the R-R interval significantly affected the CT-FT-derived strain values. The 5% R-R increment resulted in significantly larger absolute strain values. LV GRS had the greatest difference between the two groups. In the subgroups with heart rates greater than 80 beats per minute or impaired cardiac function, group differences were attenuated, especially for LV GLS, LV GRS, and LA GLS. The prevalence of definite demarcation between the LA conduit and contraction phases was significantly higher in the 5% R-R reconstruction increment group than in the 10% R-R reconstruction increment group. The average heart rate during CCTA scanning was a strong risk factor for indefinite demarcation, which is independent of LVEF. As average heart rate increased, so did the incidence of indefinite demarcation between the LA conduit and contraction phases. The observer reproducibility of LV and LA strain values was independent of the R-R reconstruction increment.
CONCLUSION: Reconstruction increment of the R-R interval is an important source of variation in LV and LA CT-FT strain values, especially with low heart rate and preserved cardiac function. It is essential to control the heart rate and apply a narrow R-R reconstruction increment to quantify phasic LA strain.
引用
- Chen, Tang, Wang, et al. Influence of temporal resolution on computed tomography feature-tracking strain measurements. Eur J Radiol. 2022. PMID: 36525702. doi:10.1016/j.ejrad.2022.110644
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。