深度学习降噪用于1mm非门控低剂量胸部CT冠状动脉钙化评分
本研究回顾性纳入131例同日行低剂量胸部CT和钙化CT的参与者,比较1mm深度学习降噪、1mm迭代重建和3mm低剂量CT的钙化评分与钙化CT参考标准的一致性。所有低剂量CT数据集均与钙化CT一致性极佳,但钙化评分被低估;1mm深度学习降噪的分类准确率最高(90%),但差异无统计学意义(p=0.10)。
要点
- 1mm深度学习降噪低剂量胸部CT可用于冠状动脉钙化评分,与钙化CT一致性极佳。
- 低剂量CT各重建方案均低估钙化评分,但分类一致性仍高。
- 1mm深度学习降噪的分类准确率(90%)略优于迭代重建和3mm层厚。
局限性
- 回顾性研究设计。
- 单中心、样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate performance of 1-mm, sharp kernel, low-dose chest computed tomography (LDCT) for coronary artery calcium scoring (CACS) using deep learning (DL)-based denoising technique.
METHODS: This retrospective, intra-individual comparative study consisted of four image datasets of 131 participants who underwent LDCT and calcium CT on the same day between January and February 2020; 1-mm LDCT with DL, 1-mm LDCT with iterative reconstruction (IR), 3-mm LDCT, and calcium CT. CACS from calcium CT were considered as reference and CACS were categorized as 0, 1-10, 11-100, 101-400, and > 400. We compared CACS from LDCTs with that from calcium CT.
RESULTS: Mean CACS was 104.8 ± 249.1 and proportion of positive CACS was 45% (59/131). CACS from LDCT images tended to be underestimated than those from calcium CT: 1-mm LDCT with DL (93.5 ± 249.6, p = 0.002), 1-mm LDCT with IR (94.7 ± 249.9, p < 0.001), and 3-mm LDCT (90.3 ± 245.3, p = 0.004). All LDCT datasets showed excellent agreement with calcium CT: intraclass correlation coefficient (ICC) = 0.961 (95% confidence interval (CI), 0.945-0.972) for DL, 0.969 (95% CI, 0.956-0.978) for IR, and 0.952 (95% CI, 0.932-0.966) for 3-mm LDCT; weighted kappa for CACS classification, 0.930 (95% CI, 0.893-0.966) for 1-mm LDCT with DL, 0.908 (95% CI, 0.866-0.950) for 1-mm LDCT with IR, and 0.846 (95% CI, 0.780-0.912) for 3-mm LDCT. The accuracy of CACS classification of 1-mm LDCT with DL (90%) tended to be better than 1-mm LDCT with IR (87%) and 3-mm LDCT (84.7%) (p = 0.10).
CONCLUSION: DL-based noise reduction algorithm can offer reliable calcium scores in 1-mm LDCT reconstructed with sharp kernel.
KEY POINTS: • Deep learning (DL)-based noise reduction enables calcium scoring at 1-mm, sharp kernel reconstructed low-dose chest CT (LDCT). • Both iterative reconstruction and DL-based noise reduction underestimated calcium score, but agreement were excellent with those from calcium CT. • Accuracy of categorical classification of calcium scoring tended to be highest in 1-mm LDCT with DL compared to 1-mm LDCT with IR and 3-mm LDCT (90%, 87%, and 84.7%, p = 0.10).
引用
- Choi, Park, Ahn, et al. Performance of 1-mm non-gated low-dose chest computed tomography using deep learning-based noise reduction for coronary artery calcium scoring. Eur Radiol. 2022. PMID: 36520181. doi:10.1007/s00330-022-09300-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。