文献速递骨肌CT

常规胸部CT联合OSTA工具筛查骨质疏松

Routine chest CT combined with the osteoporosis self-assessment tool for Asians (OSTA): a screening tool for patients with osteoporosis.
PubMed 文献 · Skeletal Radiol · 2022-12-15

本研究纳入1268例(男586、女682)受试者,评估OSTA单独、CT-T7单独及两者联合诊断骨质疏松的价值。结果显示CT-T7的AUC高于OSTA,女性联合模型AUC达0.853,高于CT-T7单独(P<0.01);MLR为2.65时敏感度53.9%、特异度90%。结论推荐胸部CT已完成者联合CT-T7与OSTA识别骨质疏松高危人群,女性MLR>2.65需进一步DXA检查。

要点

  • 胸部CT第7胸椎HU值可机会性评估骨质疏松,诊断价值优于OSTA。
  • 女性联合OSTA与CT-T7的MLR模型AUC 0.853,优于CT-T7单独。
  • 女性MLR>2.65提示骨质疏松高风险,建议进一步DXA检查。

核心结论

  • 对于已完成胸部CT的患者,推荐联合CT-T7(HU)与OSTA识别骨质疏松高危人群,诊断价值高于单独OSTA或单独CT-T7,女性尤为明显。
  • 女性MLR大于2.65者需进一步行DXA检查。

研究设计与样本

  • 本研究为诊断价值研究,纳入1268例参与者,其中男性586例、女性682例。
  • 通过联合CT-T7与OSTA建立多元线性回归模型,采用ROC曲线评估诊断骨质疏松的能力。

关键影像表现/征象

  • 男性组平均年龄59.02岁,108例(18.4%)患骨质疏松;女性组平均年龄63.23岁,308例(45.2%)患骨质疏松。

诊断标准与关键数值

  • CT-T7诊断骨质疏松的AUC:男性0.789(95%CI 0.745-0.832),女性0.835(95%CI 0.805-0.864)。
  • OSTA诊断骨质疏松的AUC:男性0.673(95%CI 0.620-0.726),女性0.775(95%CI 0.741-0.810)。
  • CT-T7的AUC在男女两组均大于OSTA(p<0.001)。
  • 女性联合模型MLR公式为:3.020-0.028*OSTA-0.004*CT-T7;女性组MLR诊断骨质疏松的AUC为0.853(95%CI 0.825-0.880),大于CT-T7(p<0.01)。
  • MLR为2.65时,敏感度53.9%、特异度90%。

临床应用与阅片要点

  • 胸部CT阅片时可测量第7胸椎HU值(CT-T7),结合OSTA评分机会性筛查骨质疏松高危人群。
  • 女性患者联合模型MLR大于2.65时,报告可提示骨质疏松高风险并建议DXA进一步检查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: The osteoporosis self-assessment tool for Asians (OSTA) is a common screening tool for osteoporosis. The seventh thoracic CT (CT-T7) Hounsfield unit (HU) measured by chest CT correlates with osteoporosis. This study aimed to investigate the diagnostic value of OSTA alone, CT-T7 alone, or the combination of OSTA and CT-T7 in osteoporosis.

MATERIALS AND METHODS: In this study, 1268 participants were grouped into 586 men and 682 women. We established multiple linear regression models by combining CT-T7 and OSTA. Receiver operating characteristic (ROC) curves were used to evaluate the ability to diagnose osteoporosis.

RESULTS: In the male group, the mean age was 59.02 years, and 108 patients (18.4%) had osteoporosis. In the female group, the mean age was 63.23 years, and 308 patients (45.2%) had osteoporosis. By ROC curve comparison, the CT-T7 (male, AUC = 0.789, 95% CI 0.745-0.832; female, AUC = 0.835, 95% CI 0.805-0.864) in the diagnosis of osteoporosis was greater than the OSTA (male, AUC = 0.673, 95% CI 0.620-0.726; female, AUC = 0.775, 95% CI 0.741-0.810) in both the male and female groups (p < 0.001). When OSTA was combined with CT, the equation of multiple linear regression (MLR) was obtained as follows: female = 3.020-0.028*OSTA-0.004*CT-T7. In the female group, it was found that the AUC of MLR (AUC = 0.853, 95% CI 0.825-0.880) in the diagnosis of osteoporosis was larger than that of CT-T7 (p < 0.01). When the MLR was 2.65, the sensitivity and specificity were 53.9% and 90%, respectively.

CONCLUSION: For a patient who has completed chest CT, CT-T7 (HU) combined with OSTA is recommended to identify the high-risk population of osteoporosis, and it has a higher diagnostic value than OSTA alone or CT-T7 alone, especially among females. For a female with MLR greater than 2.65, further DXA examination is needed.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Zhou, Luo, et al. Routine chest CT combined with the osteoporosis self-assessment tool for Asians (OSTA): a screening tool for patients with osteoporosis. Skeletal Radiol. 2022. PMID: 36520217. doi:10.1007/s00256-022-04255-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。