文献速递骨肌MR

肌肉骨骼MRI召回检查的原因与诊断价值

Causes and diagnostic utility of musculoskeletal MRI recall examinations.
PubMed 文献 · Clin Radiol · 2022-12-12

单中心10年回顾性研究显示,肌肉骨骼MRI召回率为0.25%(156/62,930),召回原因以放射科医师相关错误(33%)和技术员相关错误(35%)最常见,42%的召回导致最终报告改变。放射科医师方案/视野错误及意外病变召回显著改变报告,而技术员错误、患者运动伪影或方案错误未导致显著改变。

要点

  • 肌肉骨骼MRI召回率低(0.25%),最常见原因为视野错误、方案错误和意外病变。
  • 放射科医师相关错误(方案/视野)召回显著改变最终报告,应作为改进重点。
  • 技术员错误、患者运动伪影或方案错误召回未显著改变报告。

局限性

  • 单中心回顾性研究
  • 仅纳入要求返回追加成像的召回病例,可能存在选择偏倚

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To determine the causes and diagnostic utility of musculoskeletal (MSK) magnetic resonance imaging (MRI) recall examinations.

MATERIALS AND METHODS: An institutional review board-approved retrospective review was conducted of all MSK MRI examinations performed at a single academic institution over 10 years where radiologists requested the patient return for additional imaging. The reason for the recall was documented. Recalls were reviewed in consensus by two MSK radiologists to determine whether additional sequences resulted in a change in the final report. Recall causes were divided into four categories: (1) radiologist-related: incorrect field of view (FOV) or incorrect protocol; (2) technologist-related: incorrect FOV or incorrect/incomplete protocol performed, or technically poor-quality images; (3) patient-related motion artefact; (4) unexpected lesion discovered. Fisher's exact test was used to assess for statistical significance.

RESULTS: The recall rate was 0.25% (156/62,930). Of the total 129 recalls returning for imaging, 42 (33%) were radiologist-related, 45 (35%) were technologist-related, six (5%) were patient-related, and 36 (28%) had an unexpected lesion requiring additional sequences. For clinical utility, 42% resulted in a change from the initial report. Recalls due to radiologist error, incorrect FOV, or unexpected lesion caused a significant change in the final report; however, recalls due to technologist error, patient motion artefact, or incorrect protocol did not.

CONCLUSION: MRI MSK recalls are uncommon, and the most common reasons are incorrect FOV, incorrect protocol, and unexpected lesion. Radiologist-related errors in protocols and FOV led to a significant change in the final report and should be targeted as areas for improvement to reduce recall examinations.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Komarraju, Maxwell, Kung, et al. Causes and diagnostic utility of musculoskeletal MRI recall examinations. Clin Radiol. 2022. PMID: 36517267. doi:10.1016/j.crad.2022.11.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。