文献速递泌尿生殖腹部MR

前列腺MRI膜部尿道长度标准化测量方法观察者间与观察者内一致性高

A standardized method to measure the membranous urethral length (MUL) on MRI of the prostate with high inter- and intra-observer agreement.
PubMed 文献 · Eur Radiol · 2022-12-13

本研究在前列腺癌术前MRI上采用基于矢状位T2加权图像明确定义的解剖标志测量膜部尿道长度(MUL),由三名放射科医生对106例患者独立回顾性测量,初始观察者间ICC为0.63,经讨论统一解剖定义后升至0.84,观察者内ICC分别为0.93和0.98,结论为MUL可可靠测量且一致性高。

要点

  • 测量MUL需基于矢状位T2加权图像明确尾侧点(阴茎根部)解剖定义以保证一致性。
  • 统一解剖定义后观察者间ICC达0.84,观察者内ICC达0.93-0.98。
  • MUL是可重复测量的指标,有助于预测机器人辅助根治性前列腺切除术后尿控。

核心结论

  • 前列腺MRI上膜部尿道长度(MUL)可在放射科医生间以高一致性可靠测量。
  • 讨论并统一正确解剖定义后,观察者间和观察者内一致性均达高水平。

研究设计与样本

  • 单中心高容量机器人辅助根治性前列腺切除(RARP)中心的前列腺癌患者术前MRI回顾性研究。
  • 共纳入106例患者,由三名放射科医生独立盲法测量MUL,参考标准为基于矢状位T2加权解剖图像的明确定义标志。
  • 计算观察者间和观察者内一致性,以组内相关系数(ICC)表示。

关键影像表现/征象

  • MUL定义为矢状位T2加权图像上从前列腺尖至阴茎根部的长度。
  • 放射科医生3因对MUL尾侧点(阴茎根部)解剖定义不同,测量值平均较其他读者长3.9 mm(SD 3.3)。

诊断标准与关键数值

  • 初始观察者间一致性ICC 0.63(95%CI 0.28-0.81)。
  • 讨论正确解剖定义后放射科医生3重新评估所有扫描,观察者间一致性ICC 0.84(95%CI 0.66-0.91)。
  • 随后放射科医生1和2重新阅片,观察者内一致性分别为ICC 0.93(95%CI 0.89-0.96)和ICC 0.98(95%CI 0.97-0.98)。

临床应用与阅片要点

  • 日常阅片测量MUL时应严格遵循矢状位T2加权图像上明确定义的解剖标志,尤其注意统一尾侧点(阴茎根部)的判定。
  • 统一解剖定义可提高测量可重复性,进而提升基于MUL的RARP术后尿控预测模型的临床实用性。

局限性

  • 研究为单中心设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The membranous urethral length (MUL), defined as the length between the apex and penile base as measured on preoperative prostate magnetic resonance imaging (MRI), is an important predictor for urinary incontinence after radical prostatectomy. Literature on inter- and intra - observer agreement of MUL measurement is limited. We studied the inter- and intra-observer agreement between radiologists using a well-defined method to measure the MUL on the prostate MRI.

METHODS: Prostate cancer patients underwent a preoperative MRI and robot-assisted radical prostatectomy (RARP) at one high-volume RARP center. MUL measurement was based on well-defined landmarks on sagittal T2-weighted (anatomical) images. Three radiologists independently performed MUL measurements retrospectively in 106 patients blinded to themselves, to each other, and to clinical outcomes. The inter- and intra-observer agreement of MUL measurement between the radiologists were calculated, expressed as intra-class correlation coefficient (ICC).

RESULTS: The initial inter-observer agreement was ICC 0.63; 95% confidence interval (CI) 0.28-0.81. Radiologist 3 measured the MUL mean 3.9 mm (SD 3.3) longer than the other readers, interpreting the caudal point of the MUL (penile base) differently. After discussion on the correct anatomical definition, radiologist 3 re-assessed all scans, which resulted in a high inter-observer agreement (ICC 0.84; 95% CI 0.66-0.91). After a subsequent reading by radiologists 1 and 2, the intra-observer agreements were ICC 0.93; 95% CI 0.89-0.96, and ICC 0.98; 95% CI 0.97-0.98, respectively. Limitation is the monocenter design.

CONCLUSIONS: The MUL can be measured reliably with high agreement among radiologists.

KEY POINTS: • After discussion on the correct anatomical definition, the inter- and intra - observer agreements of membranous urethral length (MUL) measurement on magnetic resonance imaging (MRI) were high. • A reproducible method to measure the MUL can improve the clinical usefulness of prediction models for urinary continence after RARP which may benefit patient counselling.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Veerman, Hagens, Hoeks, et al. A standardized method to measure the membranous urethral length (MUL) on MRI of the prostate with high inter- and intra-observer agreement. Eur Radiol. 2022. PMID: 36512044. doi:10.1007/s00330-022-09320-2