文献速递胸部CT

人工智能CT识别联合血清自身抗体提高术前恶性肺结节诊断效率

Improving the efficiency of identifying malignant pulmonary nodules before surgery via a combination of artificial intelligence CT image recognition and serum autoantibodies.
PubMed 文献 · Eur Radiol · 2022-12-08

本研究纳入424例接受术前7种自身抗体(7-AAB)检测、基于CT的人工智能诊断及手术病理诊断的放射性肺结节患者,随机分为训练集和验证集各212例,构建基于年龄、AI诊断、7-AAB panel及CEA的列线图模型。验证集中模型敏感度82.29%、特异度90.48%、阳性预测值97.24%、AUC 0.899(95%CI 0.851-0.936),对≤2 cm结节特异度高于AI系统(90.00% vs 67.50%,p=0.022)。

要点

  • 联合7-AAB、AI及CEA的列线图可辅助鉴别良恶性肺结节,尤其≤2 cm结节。
  • 模型特异度显著高于AI诊断(90.48% vs 69.04%,p=0.022),减少假阳性。
  • 模型敏感度显著高于7-AAB panel(82.29% vs 35.88%,p<0.001)和CEA(82.29% vs 18.82%,p<0.001)。

局限性

  • 单中心回顾性研究,样本量有限。
  • 仅在验证集进行内部验证,缺乏外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To construct a new pulmonary nodule diagnostic model with high diagnostic efficiency, non-invasive and simple to measure.

METHODS: This study included 424 patients with radioactive pulmonary nodules who underwent preoperative 7-autoantibody (7-AAB) panel testing, CT-based AI diagnosis, and pathological diagnosis by surgical resection. The patients were randomly divided into a training set (n = 212) and a validation set (n = 212). The nomogram was developed through forward stepwise logistic regression based on the predictive factors identified by univariate and multivariate analyses in the training set and was verified internally in the verification set.

RESULTS: A diagnostic nomogram was constructed based on the statistically significant variables of age as well as CT-based AI diagnostic, 7-AAB panel, and CEA test results. In the validation set, the sensitivity, specificity, positive predictive value, and AUC were 82.29%, 90.48%, 97.24%, and 0.899 (95%[CI], 0.851-0.936), respectively. The nomogram showed significantly higher sensitivity than the 7-AAB panel test result (82.29% vs. 35.88%, p < 0.001) and CEA (82.29% vs. 18.82%, p < 0.001); it also had a significantly higher specificity than AI diagnosis (90.48% vs. 69.04%, p = 0.022). For lesions with a diameter of ≤ 2 cm, the specificity of the Nomogram was higher than that of the AI diagnostic system (90.00% vs. 67.50%, p = 0.022).

CONCLUSIONS: Based on the combination of a 7-AAB panel, an AI diagnostic system, and other clinical features, our Nomogram demonstrated good diagnostic performance in distinguishing lung nodules, especially those with ≤ 2 cm diameters.

KEY POINTS: • A novel diagnostic model of lung nodules was constructed by combining high-specific tumor markers with a high-sensitivity artificial intelligence diagnostic system. • The diagnostic model has good diagnostic performance in distinguishing malignant and benign pulmonary nodules, especially for nodules smaller than 2 cm. • The diagnostic model can assist the clinical decision-making of pulmonary nodules, with the advantages of high diagnostic efficiency, noninvasive, and simple measurement.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ding, Zhang, Zhuang, et al. Improving the efficiency of identifying malignant pulmonary nodules before surgery via a combination of artificial intelligence CT image recognition and serum autoantibodies. Eur Radiol. 2022. PMID: 36480027. doi:10.1007/s00330-022-09317-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。