文献速递胸部CT

超高清光子计数探测器CT肺部成像:重建核与层厚对图像质量的影响

Ultrahigh-Resolution Photon-Counting Detector CT of the Lungs: Association of Reconstruction Kernel and Slice Thickness With Image Quality.
PubMed 文献 · AJR Am J Roentgenol · 2022-12-07

本研究回顾性纳入29例非增强胸部CT患者,采用超高清模式(1024×1024矩阵)和三种重建核(BI56、BI60、BI64)与三种层厚(0.2、0.4、1.0 mm)组合,比较图像质量。结果显示仅BI64联合0.4 mm层厚在改善支气管分支识别、支气管壁和肺裂锐利度的同时,不损失肺血管锐利度及结节和其他病变的可见性。

要点

  • BI64联合0.4 mm层厚可优化支气管和肺裂显示,且不降低血管和结节可见性。
  • 更薄层厚(0.2 mm)联合BI56或BI60可能降低血管锐利度和病变可见性。
  • 临床参考重建为BI64联合1.0 mm层厚,可作为基线比较。

诊断标准与关键数值

  • 与临床参考重建相比,BI56 1.0 mm、BI60 0.4 mm、BI56 0.4 mm、BI64 0.2 mm、BI60 0.2 mm和BI56 0.2 mm的肺血管锐利度中位差值更低(分别为-0.3、-0.3、-0.7、-0.7、-0.7、-0.7)。

局限性

  • 回顾性研究,样本量较小(29例),单中心。
  • 仅评估了三种重建核和三种层厚的组合,未涉及其他参数。
  • 读者评估为 pooled 分析,未报告读者间一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. Prior work has shown improved image quality for photon-counting detector (PCD) CT of the lungs compared with energy-integrating detector CT. A paucity of the literature has compared PCD CT of the lungs using different reconstruction parameters. OBJECTIVE. The purpose of this study is to the compare the image quality of ultra-high-resolution (UHR) PCD CT image sets of the lungs that were reconstructed using different kernels and slice thicknesses. METHODS. This retrospective study included 29 patients (17 women and 12 men; median age, 56 years) who underwent noncontrast chest CT from February 15, 2022, to March 15, 2022, by use of a commercially available PCD CT scanner. All acquisitions used UHR mode (1024 × 1024 matrix). Nine image sets were reconstructed for all combinations of three sharp kernels (BI56, BI60, and BI64) and three slice thicknesses (0.2, 0.4, and 1.0 mm). Three radiologists independently reviewed reconstructions for measures of visualization of pulmonary anatomic structures and pathologies; reader assessments were pooled. Reconstructions were compared with the clinical reference reconstruction (obtained using the BI64 kernel and a 1.0-mm slice thickness [BI641.0-mm]). RESULTS. The median difference in the number of bronchial divisions identified versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.5), BI600.4-mm (0.3), BI640.2-mm (0.5), and BI600.2-mm (0.2) (all p < .05). The median bronchial wall sharpness versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.3) and BI640.2-mm (0.3) and was lower for BI561.0-mm (-0.7) and BI560.4-mm (-0.3) (all p < .05). Median pulmonary fissure sharpness versus the clinical reference reconstruction was higher for reconstructions with BI640.4-mm (0.3), BI600.4-mm (0.3), BI560.4-mm (0.5), BI640.2-mm (0.5), BI600.2-mm (0.5), and BI560.2-mm (0.3) (all p < .05). Median pulmonary vessel sharpness versus the clinical reference reconstruction was lower for reconstructions with BI561.0-mm (-0.3), BI600.4-mm (-0.3), BI560.4-mm (-0.7), BI640.2-mm (-0.7), BI600.2-mm (-0.7), and BI560.2-mm (-0.7). Median lung nodule conspicuity versus the clinical reference reconstruction was lower for reconstructions with BI561.0-mm (-0.3) and BI560.4-mm (-0.3) (both p < .05). Median conspicuity of all other pathologies versus the clinical reference reconstruction was lower for reconstructions with BI561.0 mm (-0.3), BI560.4-mm (-0.3), BI640.2-mm (-0.3), BI600.2-mm (-0.3), and BI560.2-mm (-0.3). Other comparisons among reconstructions were not significant (all p > .05). CONCLUSION. Only the reconstruction using BI640.4-mm yielded improved bronchial division identification and bronchial wall and pulmonary fissure sharpness without a loss in pulmonary vessel sharpness or conspicuity of nodules or other pathologies. CLINICAL IMPACT. The findings of this study may guide protocol optimization for UHR PCD CT of the lungs.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Milos, Röhrich, Prayer, et al. Ultrahigh-Resolution Photon-Counting Detector CT of the Lungs: Association of Reconstruction Kernel and Slice Thickness With Image Quality. AJR Am J Roentgenol. 2022. PMID: 36475813. doi:10.2214/AJR.22.28515

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。