基于MRI PD-FS图像的影像组学检测慢性踝关节外侧不稳患者软骨与软骨下骨的细微结构改变
本研究纳入215例慢性踝关节外侧不稳(CLAI)患者和186例健康对照,基于矢状位PD-FS图像分割8个软骨区域及其对应软骨下骨区域,构建影像组学模型区分CLAI与对照。测试集中联合模型AUC为0.921,高于单独软骨模型(AUC 0.912)和软骨下骨模型(AUC 0.837),提示联合影像组学可检测CLAI相关的早期结构改变。
要点
- 联合软骨与软骨下骨影像组学模型在测试集AUC达0.921,敏感度0.844、特异度0.911。
- 单独软骨模型AUC为0.912,优于单独软骨下骨模型AUC 0.837。
- 基于矢状位PD-FS图像分割8个软骨区域及对应软骨下骨区域进行特征提取。
核心结论
- 联合软骨与软骨下骨影像组学模型在检测CLAI患者潜在早期结构改变方面表现满意,测试集AUC为0.921。
研究设计与样本
- 回顾性纳入215例CLAI患者和186例健康对照,随机分为训练集281例(患者/对照=151/130)和独立测试集120例(患者/对照=64/56)。
- 所有受试者接受踝关节MRI检查,基于矢状位PD-FS图像勾画8个软骨区域及其对应软骨下骨区域。
- 构建软骨、软骨下骨及两者联合的影像组学模型,采用ROC曲线评估模型性能。
诊断标准与关键数值
- 测试集中软骨模型AUC为0.912(95%CI 0.858-0.965,p<0.001),敏感度0.859、特异度0.893、NPV 0.848、PPV 0.902。
- 测试集中软骨下骨模型AUC为0.837(95%CI 0.766-0.907,p<0.001),敏感度0.875、特异度0.714、NPV 0.833、PPV 0.778。
- 测试集中联合模型AUC为0.921(95%CI 0.863-0.972,p<0.001),敏感度0.844、特异度0.911、NPV 0.836、PPV 0.915,其AUC高于软骨模型和软骨下骨模型。
临床应用与阅片要点
- 在CLAI患者矢状位PD-FS图像上,可关注软骨及软骨下骨区域的影像组学特征,联合模型有助于提示早期结构改变。
- 联合模型特异度较高(0.911),但敏感度(0.844)略低于单独软骨模型(0.859),阅片时需结合临床避免漏诊。
局限性
- 原文未明确报告研究局限性;本研究为单中心回顾性设计,可能存在选择偏倚。
- 影像组学模型基于特定PD-FS序列和手动勾画区域,外部推广需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To use radiomics to detect the subtle changes of cartilage and subchondral bone in chronic lateral ankle instability (CLAI) patients based on MRI PD-FS images.
MATERIALS AND METHODS: A total of 215 CLAI patients and 186 healthy controls were included and randomly split into a training set (n=281, patients/controls=151/130) and an independent test set (n=120, patients/controls=64/56). They underwent ankle MRI examinations. On sagittal PD-FS images, eight cartilage regions and their corresponding subchondral bone regions were drawn. Radiomics models of cartilage, subchondral bone and combined cartilage and subchondral bone were built to differentiate CLAI patients from controls. A receiver operating characteristic curve (ROC) was used to assess the model's performance.
RESULTS: In the test dataset, the cartilage model yielded an area under the curve (AUC) of 0.0.912 (95% confidence interval (CI): 0.858-0.965, p<0.001), a sensitivity of 0.859, a specificity of 0.893, a negative predictive value (NPV) of 0.848, and a positive predictive value (PPV) of 0.902. The subchondral bone model yielded an AUC of 0.837 (95% CI: 0.766-0.907, p<0.001), a sensitivity of 0.875, a specificity of 0.714, an NPV of 0.833, and a PPV of 0.778. For the combined model, the AUC was 0.921 (95% CI: 0.863-0.972, p<0.001), sensitivity was 0.844, specificity was 0.911, NPV was 0.836, and PPV was 0.915, whose AUC was higher than those of both the cartilage model and the subchondral bone model.
CONCLUSION: The combined radiomics model achieved satisfying performance in detecting potential early architectural changes in cartilage and subchondral bone for CLAI patients.
引用
- Tao, Dan, Hu, et al. Using Radiomics to Detect Subtle Architecture Changes of Cartilage and Subchondral Bone in Chronic Lateral Ankle Instability Patients Based on MRI PD-FS Images. Acad Radiol. 2022. PMID: 36470734. doi:10.1016/j.acra.2022.11.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。