1.5T下同时多层与常规扩散张量成像在缺血性卒中评估中的比较
本研究在1.5T MRI上比较了同时多层(SMS)与常规扩散张量成像(DTI)在缺血性卒中评估中的表现。纳入41例疑似缺血性卒中患者,SMS-2-DTI将DTI采集时间减少132.17±15.33秒(45%),图像质量有所下降,但诊断准确性(AUC)和观察者间信度(κ)与常规DTI无显著差异。结论支持在非超急性期使用SMS加速DTI进行缺血性卒中检查。
要点
- SMS-2-DTI可显著缩短DTI采集时间(减少45%),适合非超急性期卒中评估。
- SMS-2-DTI图像质量和SNR较常规DTI下降,但诊断准确性(AUC)无显著差异。
- 观察者间信度在两种DTI方法中均较高(κ≥0.80),SMS-2-DTI略高。
关键影像表现/征象
- SMS-2-DTI较STD-DTI图像质量评分降低(4.7±0.5 vs 3.8±0.6,p<.001)。
- SMS-2-DTI平均SNR显著降低(42.85±4.44 vs 32.58±4.30,p<.001)。
- CV MD在SMS-2-DTI中显著降低(0.23±0.03 vs 0.20±0.04,p<.001),CV FA和CV DTI-trace无统计学差异。
诊断标准与关键数值
- 诊断准确性以AUC评估:观察者1 STD-DTI 0.95(95%CI 0.88-1.00) vs SMS-2-DTI 0.94(95%CI 0.87-1.00),p=.86;观察者2 STD-DTI 0.89(95%CI 0.79-0.99) vs SMS-2-DTI 0.86(95%CI 0.76-0.97),p=.66。
- 观察者间信度:STD-DTI κ=0.80(95%CI 0.61-0.98),SMS-2-DTI κ=0.84(95%CI 0.67-1.00)。
- DTI序列参数:STD-DTI为20方向,b=2000 s/mm²;SMS-2-DTI为同时采集两层。
临床应用与阅片要点
- 在非超急性期缺血性卒中评估中,可采用SMS-2-DTI缩短扫描时间,但需注意图像质量和SNR下降。
- 诊断时仍应以DTI-trace图像为准,结合常规DWI序列综合判断。
局限性
- 单中心研究,样本量较小(41例)。
- 仅纳入超出治疗时间窗的疑似卒中患者,不适用于超急性期。
- 未报告敏感度、特异度等完整诊断效能指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Diffusion tensor imaging (DTI) is a promising technique for ischemic stroke evaluation; however, acquisition time is longer than DWI. Simultaneous multislice (SMS) imaging acquires multiple slices together and reduces scan time. This study compared conventional and SMS DTI for ischemic stroke workup.
METHODS: Following IRB approval, the departmental stroke protocol was supplemented with SMS DTI on a clinical 1.5T MRI. Cases suspicious for ischemic stroke outside the treatment window were included. Standard DTI (STD-DTI, 20-direction, b = 2000 s/mm2), was followed by SMS-2-DTI (two slices simultaneously imaged). Two blinded neuroradiologists independently assessed image quality and DTI-trace status (positive/negative = stroke/other). Average image quality, interrater reliability (κ), receiver operating characteristic area under the curve (AUC), signal-to-noise ratio (SNR = DTI-source min/max/average), coefficient of variation (CV), mean diffusivity (MD), and fractional anisotropy (FA, of DTI-trace) were compared using two-tailed t-tests and a p < .05.
RESULTS: 41 patients were evaluated. SMS-2-DTI decreased DTI time by 132.17 ± 15.33 s, a 45% reduction. SMS-2-DTI reduced image quality (STD-DTI 4.7 ± 0.5 vs SMS-2-DTI 3.8 ± 0.6, p < .001). Diagnostic accuracy persisted, AUC was high for observer 1 (STD-DTI 0.95, 95%CI = 0.88-1.00 vs SMS-2-DTI 0.94, 95%CI = 0.87-1.00, p = .86) and observer 2 (STD-DTI 0.89, 95%CI = 0.79-0.99 vs SMS-2-DTI 0.86, 95%CI = 0.76-0.97, p = .66). Interrater reliability was high for STD-DTI (κ = 0.80, 95%CI = 0.61-0.98) and SMS-2-DTI (κ = 0.84, 95%CI = 0.67-1.00). SMS-2-DTI significantly decreased average SNR (STD-DTI 42.85 ± 4.44 vs SMS-2-DTI 32.58 ± 4.30, p < .001), and CV MD (STD-DTI 0.23 ± 0.03 vs 0.20 ± 0.04, p < .001). CV FA and CV DTI-trace were not statistically different.
CONCLUSIONS: This study supports using SMS to accelerate DTI for ischemic stroke workup at 1.5T in the non-hyper-acute setting.
ADVANCES IN KNOWLEDGE: This study highlights the feasibility of accelerated multislice DTI for faster diagnostic DTI-trace images capable of ischemic stroke detection.
引用
- Culleton, Hashemizadeh Kolowori, Roberts, et al. A comparison of simultaneous multislice and conventional diffusion tensor imaging techniques for ischemic stroke evaluation at 1.5T. Br J Radiol. 2022. PMID: 36469531. doi:10.1259/bjr.20220222
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。