文献速递泌尿生殖MR

PI-RADS v2.1简化bpMRI与标准mpMRI对临床显著前列腺癌的诊断效能比较

The diagnostic performance in clinically significant prostate cancer with PI-RADS version 2.1: simplified bpMRI versus standard mpMRI.
PubMed 文献 · Abdom Radiol (NY) · 2022-12-05

本回顾性研究纳入569例接受mpMRI后行活检或前列腺切除术的患者,由三个中心的放射科医生分别用简化bpMRI(仅轴位T2WI)和标准mpMRI按PI-RADS v2.1评分。结果显示mpMRI的敏感度和AUC总体优于简化bpMRI,但简化bpMRI仍保持较高诊断效能,提示其可作为潜在筛查工具。

要点

  • 简化bpMRI仅用轴位T2WI,诊断csPCa的敏感度低于标准mpMRI,但整体效能仍较高。
  • PI-RADS v2.1在简化bpMRI和mpMRI中均显示良好观察者间一致性(kappa分别为0.665和0.739)。
  • 简化bpMRI可作为前列腺癌筛查的潜在工具,但标准mpMRI诊断效能更优。

核心结论

  • 简化bpMRI检测csPCa的敏感度低于标准mpMRI,但诊断效能仍较高,可作为潜在筛查工具。

研究设计与样本

  • 回顾性研究纳入569例接受mpMRI后行活检或前列腺切除术的患者。
  • 三位来自三个中心的放射科医生在不知临床变量的情况下,先后对简化bpMRI和mpMRI按PI-RADS v2.1评分,间隔2周。
  • 以组织病理学为参考标准,比较简化bpMRI与mpMRI的诊断效能。

诊断标准与关键数值

  • 三位放射科医生的敏感度均为mpMRI显著高于简化bpMRI(P < 0.001至P = 0.035)。
  • 放射科医生B和C的特异度mpMRI高于简化bpMRI,但仅医生B有统计学意义(P = 0.011和P = 0.359)。
  • 放射科医生A的特异度简化bpMRI高于mpMRI(P = 0.001)。
  • AUC比较:医生A为0.903 vs 0.913(P = 0.1542);医生B为0.861 vs 0.834(P = 0.0013);医生C为0.884 vs 0.848(P = 0.0003),除医生A外mpMRI显著更高。
  • PI-RADS v2.1观察者间一致性:简化bpMRI的kappa = 0.665,mpMRI的kappa = 0.739。

临床应用与阅片要点

  • 在日常阅片中,简化bpMRI(仅轴位T2WI)可作为筛查工具,但需注意其敏感度低于标准mpMRI。
  • 报告时应遵循PI-RADS v2.1评分,简化bpMRI与mpMRI的观察者间一致性均良好。

局限性

  • 本研究为回顾性设计。
  • 简化bpMRI仅使用轴位T2WI,可能遗漏部分信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare the diagnostic performance for the detection of clinically significant prostate cancer (csPCa) between bpMRI with only axial T2WI (simplified bpMRI) and standard-multiparametric MRI (mpMRI).

METHODS: A total of 569 patients who underwent mpMRI followed by biopsy or prostatectomy were enrolled in this retrospective study. According to PI-RADS v2.1, three radiologists (A, B, C) from three centers blinded to clinical variables were assigned scores on lesions with simplified bpMRI and then with mpMRI 2 weeks later. Diagnostic performance of simplified bpMRI was compared with mpMRI using histopathology as reference standard.

RESULTS: For all the three radiologists, the diagnostic sensitivity was significantly higher with mpMRI than with simplified bpMRI (P < 0.001 to P = 0.035); and although specificity was also higher with mpMRI than with simplified bpMRI for radiologist B and radiologist C, it was statistically significant only for radiologist B (P = 0.011, P = 0.359, respectively). On the contrary, for radiologist A, specificity was higher with simplified bpMRI than with mpMRI (P = 0.001). The area under the receiver operating characteristic curve (AUC) was significantly higher for mpMRI than for simplified bpMRI except for radiologist A (radiologist A: 0.903 vs 0.913, P = 0.1542; radiologist B: 0.861 vs 0.834 P = 0.0013; and radiologist C: 0.884 vs 0.848, P = 0.0003). Interobserver reliability of PI-RADS v2.1 showed good agreement for both simplified bpMRI (kappa = 0.665) and mpMRI (kappa = 0.739).

CONCLUSION: Although the detection of csPCa with simplified bpMRI was comparatively lower than that with mpMRI, the diagnostic performance was still high in simplified bpMRI. Our data justify using mpMRI outperforms simplified bpMRI for prostate cancer screening and imply simplified bpMRI as a potential screening tool.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Song, Zhao, Zhang, et al. The diagnostic performance in clinically significant prostate cancer with PI-RADS version 2.1: simplified bpMRI versus standard mpMRI. Abdom Radiol (NY). 2022. PMID: 36464756. doi:10.1007/s00261-022-03750-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。