全身PET/MRI中同步多层面扩散加权成像与标准扩散加权成像的比较
结果显示SMS-DWI全身采集时间中位数从14.8分钟缩短至7.0分钟,腹部图像质量更高,病灶检出率从78%提升至84%,但颈胸交界处图像质量较低。
要点
- SMS-DWI将全身DWI采集时间从14.8分钟缩短至7.0分钟。
- 腹部图像质量SMS-DWI更优,颈胸交界处更差,其余区域无差异。
- SMS-DWI病灶检出率84%优于STD-DWI的78%。
关键影像表现/征象
- SMS-DWI在腹部图像质量评分高于STD-DWI(OR 5.31,95% CI 2.76-10.22,p < 0.001)。
- SMS-DWI在颈胸交界处图像质量评分低于STD-DWI(OR 0.21,95% CI 0.10-0.43,p < 0.001)。
- 胸部、纵隔、盆腔和直肠的图像质量评分无显著差异。
诊断标准与关键数值
- STD-DWI采用b值50-400-800 s/mm²及ADC,SMS-DWI采用b值50-300-800 s/mm²及ADC。
- 图像质量由三名放射科医生采用五分制评分。
- STD-DWI检出276/352(78%)病灶,SMS-DWI检出296/352(84%),OR 1.46(95% CI 1.02-2.07,p = 0.038)。
- 全身STD-DWI采集时间中位数14.8分钟(IQR 14.1-16.0),SMS-DWI为7.0分钟(IQR 6.7-7.2),p < 0.001。
临床应用与阅片要点
- 在腹部肿瘤分期中可优先考虑SMS-DWI以缩短扫描时间并提高病灶检出。
- 颈胸交界处SMS-DWI图像质量较低,阅片时需注意该区域可能存在的伪影或细节丢失。
局限性
- 仅纳入腹部或盆腔肿瘤患者,结论外推至其他部位肿瘤需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare standard (STD-DWI) single-shot echo-planar imaging DWI and simultaneous multislice (SMS) DWI during whole-body positron emission tomography (PET)/MRI regarding acquisition time, image quality, and lesion detection.
METHODS: Eighty-three adults (47 females, 57%), median age of 64 years (IQR 52-71), were prospectively enrolled from August 2018 to March 2020. Inclusion criteria were (a) abdominal or pelvic tumors and (b) PET/MRI referral from a clinician. Patients were excluded if whole-body acquisition of STD-DWI and SMS-DWI sequences was not completed. The evaluated sequences were axial STD-DWI at b-values 50-400-800 s/mm2 and the apparent diffusion coefficient (ADC), and axial SMS-DWI at b-values 50-300-800 s/mm2 and ADC, acquired with a 3-T PET/MRI scanner. Three radiologists rated each sequence's quality on a five-point scale. Lesion detection was quantified using the anatomic MRI sequences and PET as the reference standard. Regression models were constructed to quantify the association between all imaging outcomes/scores and sequence type.
RESULTS: The median whole-body STD-DWI acquisition time was 14.8 min (IQR 14.1-16.0) versus 7.0 min (IQR 6.7-7.2) for whole-body SMS-DWI, p < 0.001. SMS-DWI image quality scores were higher than STD-DWI in the abdomen (OR 5.31, 95% CI 2.76-10.22, p < 0.001), but lower in the cervicothoracic junction (OR 0.21, 95% CI 0.10-0.43, p < 0.001). There was no significant difference in the chest, mediastinum, pelvis, and rectum. STD-DWI detected 276/352 (78%) lesions while SMS-DWI located 296/352 (84%, OR 1.46, 95% CI 1.02-2.07, p = 0.038).
CONCLUSIONS: In cancer staging and restaging, SMS-DWI abbreviates acquisition while maintaining or improving the diagnostic yield in most anatomic regions.
KEY POINTS: • Simultaneous multislice diffusion-weighted imaging enables faster whole-body image acquisition. • Simultaneous multislice diffusion-weighted imaging maintains or improves image quality when compared to single-shot echo-planar diffusion-weighted imaging in most anatomical regions. • Simultaneous multislice diffusion-weighted imaging leads to superior lesion detection.
引用
- Furtado, Mercaldo, Vahle, et al. Simultaneous multislice diffusion-weighted imaging versus standard diffusion-weighted imaging in whole-body PET/MRI. Eur Radiol. 2022. PMID: 36460925. doi:10.1007/s00330-022-09275-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。