双能CT心肌血池成像评估心肌缺血再灌注损伤患者心肌存活性
该前瞻性研究纳入59例急性心肌梗死血运重建后发生心肌缺血再灌注损伤(MIRI)的患者,于MIRI发病1周内行双能CT心肌血池成像(DECT MBPI),以SPECT静息心肌灌注显像+PET心肌代谢显像为参考标准,分析1003个心肌节段的碘值。结果显示DECT MBPI鉴别正常、缺血及梗死心肌的AUC分别为0.957、0.900、0.906,敏感度和特异度均较高,提示其可用于无创评估MIRI患者的心肌存活性。
要点
- DECT MBPI碘值可区分正常、缺血及梗死心肌,AUC均>0.9。
- 鉴别缺血与正常心肌的碘值阈值为0.84 mg I/mL
- 鉴别梗死与正常心肌的碘值阈值为2.01 mg I/mL
核心结论
- DECT MBPI可高敏感度和特异度地评估MIRI患者的心肌存活性。
研究设计与样本
- 前瞻性研究,2017年9月至2019年1月纳入59例急性心肌梗死血运重建后发生MIRI的患者,共分析1003个心肌节段。
- 所有患者于MIRI发病1周内依次接受DECT MBPI、SPECT静息心肌灌注显像和PET心肌代谢显像。
- 以SPECT静息心肌灌注显像+PET心肌代谢显像为参考标准,通过心脏碘图计算碘减低区和延迟强化区。
诊断标准与关键数值
- DECT MBPI碘值鉴别正常心肌、缺血心肌和梗死心肌的AUC分别为0.957、0.900、0.906(p < 0.001)。
- 鉴别缺血心肌的敏感度87.6%、特异度89.3%、准确率97.9%(p < 0.001)。
- 鉴别梗死心肌的敏感度88.9%、特异度92.2%、准确率98.6%(p < 0.001)。
- 鉴别缺血与正常心肌的碘值阈值为0.84 mg I/mL。
- 鉴别梗死与正常心肌的碘值阈值为2.01 mg I/mL。
临床应用与阅片要点
- 可利用DECT MBPI碘值定量评估MIRI患者心肌存活性,辅助识别缺血但存活的心肌。
- 注意梗死与正常心肌的鉴别阈值(2.01 mg I/mL)高于缺血与正常心肌的阈值(0.84 mg I/mL),阅片时应结合碘图区域分布综合判断。
局限性
- 单中心前瞻性研究,样本量59例,结论需多中心验证。
- 参考标准为SPECT+PET,非病理金标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate myocardial viability in patients with myocardial ischemia reperfusion injury (MIRI) via dual-energy computed tomography myocardial blood pool imaging (DECT MBPI).
METHODS: Between September 2017 and January 2019, we prospectively recruited 59 patients with acute myocardial infarction (AMI) who developed MIRI after revascularization during invasive coronary angiography (ICA). Then, they received DECT MBPI, SPECT, and PET sequentially within 1 week after the onset of MIRI. A total of 1003 myocardial segments of 59 patients were recruited for this study. The iodine reduction areas and delayed enhancement areas were calculated by cardiac iodine map with SPECT rest myocardial perfusion imaging (MPI) + PET myocardial metabolism imaging (MMI) as reference criteria. The paired sample t-test was used to measure the difference of the myocardial iodine value. Cohen's Kappa analysis was used to test the consistency among different observers. ROC analysis was used to calculate the myocardial viability of DECT MBPI.
RESULTS: ROC showed the AUCs of DECT MBPI iodine value to identify a normal myocardium, an ischemic myocardium, and an infarcted myocardium were 0.957, 0.900, and 0.906 (p < 0.001). The sensitivity, specificity, and accuracy of DECT MBPI in identifying an ischemic myocardium were 87.6%, 89.3%, and 97.9% (p < 0.001). The sensitivity, specificity, and accuracy of DECT MBPI in identifying an infarcted myocardium were 88.9%, 92.2%, and 98.6% (p < 0.001). The cutoff value for DECT MBPI to differentiate between an ischemic and a normal myocardium was 0.84 mg I/mL. The cutoff value for DECT MBPI to differentiate between an infarct and a normal myocardium was 2.01 mg I/mL.
CONCLUSION: DECT MBPI can be used to assess myocardial viability in patients with MIRI with high sensitivity and specificity.
KEY POINTS: • Dual-energy computed tomography myocardial blood pool imaging (DECT MBPI) can evaluate myocardial viability of myocardial ischemia-reperfusion injury (MIRI). • DECT MBPI is a non-invasive and timesaving method for evaluation on myocardial ischemia-reperfusion injury in patients with acute myocardial infarction after coronary intervention.