人工智能辅助超声诊断婴儿发育性髋关节发育不良在受限计算资源下的应用
本研究开发了自动系统DDHnet,通过分析静态超声图像诊断婴儿发育性髋关节发育不良(DDH)。在881例患者的数据集上进行五折交叉验证,并在209例患者(158例正常,51例异常)上进行盲测。DDHnet在异常病例中测量α角、β角、FHC和PFD的ICC分别为0.96、0.97、0.98和0.94,诊断敏感度90.56%、特异度100%、准确率98.64%、PPV 100%、NPV 98.44%。在超声设备上完成测量仅需1.1秒,而资深专家平均需41.4秒。
要点
- DDHnet在低计算成本下嵌入超声机,实现快速自动测量与诊断。
- 诊断特异度达100%,敏感度90.56%,准确率98.64%。
- 测量α角、β角、FHC、PFD的ICC均高于0.94,可靠性高。
英文原文(摘要)· 点击展开
OBJECTIVES: Ultrasound (US) is important for diagnosing infant developmental dysplasia of the hip (DDH). However, the accuracy of the diagnosis depends heavily on expertise. We aimed to develop a novel automatic system (DDHnet) for accurate, fast, and robust diagnosis of DDH.
METHODS: An automatic system, DDHnet, was proposed to diagnose DDH by analyzing static ultrasound images. A five-fold cross-validation experiment was conducted using a dataset containing 881 patients to verify the performance of DDHnet. In addition, a blind test was conducted on 209 patients (158 normal and 51 abnormal cases). The feasibility and performance of DDHnet were investigated by embedding it into ultrasound machines at low computational cost.
RESULTS: DDHnet obtained reliable measurements and accurate diagnosis predictions. It reported an intra-class correlation coefficient (ICC) on α angle of 0.96 (95% CI: 0.93-0.97), β angle of 0.97 (95% CI: 0.95-0.98), FHC of 0.98 (95% CI: 0.96-0.99) and PFD of 0.94 (95% CI: 0.90-0.96) in abnormal cases. DDHnet achieved a sensitivity of 90.56%, specificity of 100%, accuracy of 98.64%, positive predictive value (PPV) of 100%, and negative predictive value (NPV) of 98.44% for the diagnosis of DDH. For the measurement task on the US device, DDHnet took only 1.1 seconds to operate and complete, whereas the experienced senior expert required an average 41.4 seconds.
CONCLUSIONS: The proposed DDHnet demonstrate state-of-the-art performance for all four indicators of DDH diagnosis. Fast and highly accurate DDH diagnosis is achievable through DDHnet, and is accessible under constrained computational resources.
引用
- Huang, Xia, Qian, et al. Artificial Intelligence-Assisted Ultrasound Diagnosis on Infant Developmental Dysplasia of the Hip Under Constrained Computational Resources. J Ultrasound Med. 2022. PMID: 36445006. doi:10.1002/jum.16133
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。