文献速递技术与安全DR

X射线散射校正软件在诊断X射线成像中的原理与有效性:范围综述

The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review.
PubMed 文献 · Eur J Radiol · 2022-11-17

本范围综述系统检索了2000至2021年间关于X射线散射校正软件的文献,最终纳入11篇研究。研究表明,散射校正软件在图像质量和降低辐射剂量方面有效,但传统滤线栅仍提供更高的图像质量。该软件临床应用目前限于特定部位。

要点

  • 散射校正软件可在不使用滤线栅的情况下减少散射,降低患者剂量。
  • 传统滤线栅的图像质量仍优于散射校正软件。
  • 临床应用目前限于颈椎、胸部、肩部、腰椎、髋部和骨盆。

核心结论

  • X射线散射校正软件在特定情况下有效并具有潜在益处,但传统滤线栅图像质量更高。

研究设计与样本

  • 范围综述,检索PubMed、Scopus和Web of Science,纳入2000年1月1日至2021年12月31日关于X射线散射校正软件的文献,最终11篇纳入数据合成。
  • 研究人群包括患者、图像质量体模和解剖体模。

临床应用与阅片要点

  • 在无滤线栅或需降低剂量时,可考虑使用散射校正软件,但需注意其图像质量可能低于传统滤线栅。
  • 目前证据仅支持在颈椎、胸部、肩部、腰椎、髋部和骨盆等部位应用。

局限性

  • 纳入研究数量较少(11篇),研究人群异质(患者与体模),临床证据有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: An anti-scatter grid is often used in X-ray radiography to reduce the scattered X-rays generated from the patient. However, the presence of a grid means the patient dose subsequently increases. Recently,severalmanufacturers have developedsoftwarethat is capable of correctingfor scattered X-rays withouttheuse ofa conventional grid. This scoping review aims to systematically map the research assessing scattering correction software and to identify any existing knowledge gaps.

METHODS: This scoping review involved conducting a systematic search in PubMed, Scopus, and Web of science to reveal studies that were relevant to the research question. Articles published between 01.01.2000 and 31.12.2021 examining X-ray scatter correction software for X-ray imaging were included. A part of the PRISMA model and PICO framework were utilised to establish eligibility criteria. A structured summary table was utilised to extract data from the selected articles.

RESULTS: In this scoping review, 20 years of literature in X-ray conventional radiography. 11 articles were included in the data synthesis. The study populations of the included studies were varied: patients, image quality phantoms and anatomical phantoms. The clinical applications of X-ray scatter correction software were found to be limited to specific body parts (cervical spine, chest, shoulder, lumbar spine, hip and pelvis). The scatter correction software appears to be effective in terms of image quality and in reducing the radiation dose. However, the conventional grid still provides a higher image quality.

CONCLUSIONS: X-ray scatter correction software can be effective and provides potentialbenefits for some circumstances or clinical scenarios.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Sayed, Knapp, Fulford, et al. The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review. Eur J Radiol. 2022. PMID: 36444818. doi:10.1016/j.ejrad.2022.110600

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。