文献速递心血管CTMR

新型CT扫描仪综合评估左心室功能障碍:E-PLURIBUS研究

Comprehensive Evaluation of Left Ventricle Dysfunction by a New Computed Tomography Scanner: The E-PLURIBUS Study.
PubMed 文献 · JACC Cardiovasc Imaging · 2022-10-19

本研究纳入94例新诊断左心室功能障碍患者,比较心脏CT(CCT)与心脏磁共振(CMR)在评估双心室容积、射血分数及延迟强化(DE)方面的一致性。CCT与CMR提示病因的一致率为94.7%,识别缺血性心肌病达100%;基于节段的DE诊断准确率为94.8%(95%CI:93.6%-95.8%)。CCT全扫描平均辐射剂量为7.78±2.53 mSv(DE序列为0.84±0.24 mSv)。

要点

  • CCT可准确评估双心室容积、射血分数及延迟强化,与CMR高度一致。
  • CCT识别缺血性心肌病的病因一致率达100%,DE节段诊断准确率94.8%。
  • 全心脏覆盖低剂量扫描方案辐射剂量约7.78 mSv,DE序列仅0.84 mSv。

核心结论

  • 低剂量全心脏覆盖扫描仪联合高浓度对比剂的心脏CT可有效无创地综合评估新诊断左心室功能障碍患者。

研究设计与样本

  • 前瞻性研究,连续筛查128例新诊断左心室功能障碍患者,排除28例后,6例因CMR幽闭恐惧症被排除,最终94例构成研究人群。
  • CCT在CMR后10天内进行,评估双心室容积、射血分数及延迟强化(DE)的存在与模式;部分患者在CCT后6个月内接受侵入性血管造影以评估冠状动脉。

关键影像表现/征象

  • CCT与CMR在提示左心室功能障碍病因方面一致率高(94.7%,89/94例),识别缺血性心肌病的一致率为100%。
  • CCT对DE的诊断率(96.7%,1544/1598个节段)与CMR(97.4%)相似,差异无统计学意义(P=0.345)。
  • CCT与CMR测量的双心室容积和功能参数相似,除右心室容积有轻微差异外,无其他显著差异。

诊断标准与关键数值

  • 基于节段分析,CCT检测DE的诊断准确率为94.8%(95%CI:93.6%-95.8%)。
  • CCT评估冠状动脉循环的准确性得到确认。

临床应用与阅片要点

  • 对于新诊断左心室功能障碍患者,CCT可作为一站式无创工具,同时评估心脏功能、心肌纤维化及冠状动脉。
  • DE序列辐射剂量低(0.84±0.24 mSv),可在常规CCT中附加用于心肌组织 characterization。

局限性

  • 单中心研究,样本量有限(94例),部分患者因幽闭恐惧症被排除。
  • 仅部分患者接受了侵入性血管造影验证冠状动脉评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Although cardiac magnetic resonance (CMR) is considered the gold standard for myocardial fibrosis detection, cardiac computed tomography (CCT) is emerging as a promising alternative.

OBJECTIVES: The purpose of this study was to assess feasibility and diagnostic accuracy of a comprehensive functional and anatomical evaluation with CCT as compared with CMR in patients with newly diagnosed left ventricular dysfunction (LVD).

METHODS: A total of 128 consecutive patients with newly diagnosed LVD were screened. Based on the exclusion criteria, 28 cases were excluded. CCT was performed within 10 days from CMR. Biventricular volumes and ejection fraction, and presence and pattern of delayed enhancement (DE), were determined, along with evaluation of coronary arteries among patients undergoing invasive angiography in the 6 months after CCT.

RESULTS: Six cases were excluded because of claustrophobia at CMR. Among the 94 patients who formed the study population, the concordance between CCT and CMR in suggesting the cause of the LVD was high (94.7%, 89/94 patients) in the overall population and was 100% for identifying ischemic cardiomyopathy. The CCT diagnostic rate for DE assessment was also high (96.7%, 1,544/1,598 territories) and similar to that of CMR (97.4%; P = 0.345, CCT vs CMR). Moreover, CCT showed high diagnostic accuracy in the detection of DE (94.8%, 95% CI: 93.6%-95.8%) in a territory-based analysis. Biventricular volumes and function parameters as measured by CCT and CMR were similar, without significant differences with the exception of a modest difference in RV volume. CCT was confirmed to be accurate for assessing arterial coronary circulation. The mean radiation exposure of the whole CCT was 7.78 ± 2.53 mSv (0.84 ± 0.24 mSv for DE).

CONCLUSIONS: CCT performed with low-dose whole-heart coverage scanner and high-concentration contrast agent appears an effective noninvasive tool for a comprehensive assessment of patients with newly diagnosed LVD.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Andreini, Conte, Mushtaq, et al. Comprehensive Evaluation of Left Ventricle Dysfunction by a New Computed Tomography Scanner: The E-PLURIBUS Study. JACC Cardiovasc Imaging. 2022. PMID: 36444769. doi:10.1016/j.jcmg.2022.08.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。