文献速递骨肌儿科影像技术与安全MRPET

弥散加权MRI检测儿童及年轻成人实体瘤骨髓转移

Detection of bone marrow metastases in children and young adults with solid cancers with diffusion-weighted MRI.
PubMed 文献 · Skeletal Radiol · 2022-11-28

该前瞻性研究纳入19例儿童及年轻成人实体瘤患者,共51次全身DW-MRI扫描,以18F-FDG-PET为标准参照,比较b=50与b=800 s/mm2图像的诊断准确性。结果显示两种b值图像对骨髓转移灶的检出数目相同(556/588,94.6%),但ADC图上正常骨髓与转移灶均呈低信号,ADC值可能误导诊断。

要点

  • b=50与b=800 s/mm2图像对骨髓转移灶检出能力相当,无需仅依赖高b值图像。
  • ADC图上正常骨髓与转移灶均呈低信号,ADC值不能可靠区分两者。
  • 治疗后 reconverted 骨髓在ADC图上呈低信号且ADC值低,需警惕假阳性。

关键影像表现/征象

  • b=50 s/mm2图像上骨髓转移灶SNR显著高于正常骨髓(978.436±1239.436 vs. 108.881±109.813,p<0.001)。
  • b=800 s/mm2图像上骨髓转移灶SNR亦显著高于正常骨髓(499.638±612.721 vs. 86.280±89.120,p<0.001)。
  • 32次治疗后DW-MRI扫描中30次显示 reconverted 骨髓呈低信号且ADC值低(0.385×10-3±0.168×10-3 mm2/s)。
  • ADC图上正常骨髓与转移灶均呈低信号,限制了对转移灶的 delineation。

诊断标准与关键数值

  • b=50 s/mm2与b=800 s/mm2图像检出相同数目的转移灶(556/588,94.6%,p>0.99)。
  • 读者间一致性为实质性,加权kappa分别为0.783和0.778。

临床应用与阅片要点

  • 阅片时b=50与b=800 s/mm2图像均可用于检出骨髓转移灶,不必仅依赖单一b值。
  • ADC图上正常骨髓与转移灶均可呈低信号,不应仅凭ADC值判断转移。
  • 治疗后骨髓 reconversion 可表现为低信号伴低ADC值,需结合临床和其他序列避免误判。

局限性

  • 单中心前瞻性研究,样本量较小(19例患者)。
  • 以18F-FDG-PET为标准参照,可能存在参考标准本身的不确定性。
  • ADC值在正常骨髓与转移灶间重叠,限制了其鉴别价值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic accuracy of diffusion-weighted (DW)-MRI with b-values of 50 s/mm2 and 800 s/mm2 for the detection of bone marrow metastases in children and young adults with solid malignancies.

METHODS: In an institutional review board-approved prospective study, we performed 51 whole-body DW-MRI scans in 19 children and young adults (14 males, 5 females; age range: 1-25 years) with metastasized cancers before (n = 19 scans) and after (n = 32 scans) chemotherapy. Two readers determined the presence of focal bone marrow lesions in 10 anatomical areas. A third reader measured ADC and SNR of focal lesions and normal marrow. Simultaneously acquired 18F-FDG-PET scans served as the standard of reference. Data of b = 50 s/mm2 and 800 s/mm2 images were compared with the Wilcoxon signed-rank test. Inter-reader agreement was evaluated with weighted kappa statistics.

RESULTS: The SNR of bone marrow metastases was significantly higher compared to normal bone marrow on b = 50 s/mm2 (mean ± SD: 978.436 ± 1239.436 vs. 108.881 ± 109.813, p < 0.001) and b = 800 s/mm2 DW-MRI (499.638 ± 612.721 vs. 86.280 ± 89.120; p < 0.001). On 30 out of 32 post-treatment DW-MRI scans, reconverted marrow demonstrated low signal with low ADC values (0.385 × 10-3 ± 0.168 × 10-3mm2/s). The same number of metastases (556/588; 94.6%; p > 0.99) was detected on b = 50 s/mm2 and 800 s/mm2 images. However, both normal marrow and metastases exhibited low signals on ADC maps, limiting the ability to delineate metastases. The inter-reader agreement was substantial, with a weighted kappa of 0.783 and 0.778, respectively.

CONCLUSION: Bone marrow metastases in children and young adults can be equally well detected on b = 50 s/mm2 and 800 s/mm2 images, but ADC values can be misleading.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Rashidi, Baratto, Jayapal, et al. Detection of bone marrow metastases in children and young adults with solid cancers with diffusion-weighted MRI. Skeletal Radiol. 2022. PMID: 36441237. doi:10.1007/s00256-022-04240-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。