文献速递乳腺US

超声直方图评估乳腺癌放疗后急性乳腺毒性:前瞻性纵向研究

Ultrasound Histogram Assessment of Acute Breast Toxicity After Breast Cancer Radiation Therapy: A Prospective Longitudinal Study.
PubMed 文献 · Ultrasound Med Biol · 2022-10-27

该前瞻性研究纳入67例乳腺癌放疗患者,在放疗前、放疗最后一天、放疗后3-4周和9-12周四个时间点进行超声扫描,分析264幅超声扫描和2640幅B模式图像。通过计算照射侧与对侧乳腺的直方图差异评估放疗引起的乳腺改变,并按B模式图像将乳腺毒性分级为无、轻度、中度或重度。ROC曲线显示直方图法在下象限区分无/轻度与中度/重度毒性的AUC为0.78-0.9,敏感度0.88-0.96,特异度0.53-0.83。

要点

  • 超声直方图差异可作为纵向评估放疗急性乳腺毒性的影像生物标志物。
  • 下象限直方图法区分无/轻度与中度/重度毒性AUC达0.78-0.9。
  • 基于B模式图像可将乳腺毒性分级为无、轻度、中度或重度。

关键影像表现/征象

  • 基于B模式图像可将放疗所致乳腺毒性分级为无、轻度、中度或重度。
  • 通过计算照射侧与对侧乳腺的直方图差异来评估放疗引起的乳腺改变。

诊断标准与关键数值

  • 在下象限区分无/轻度与中度/重度毒性时,各时间点AUC为0.78-0.9,敏感度0.88-0.96,特异度0.53-0.83。

临床应用与阅片要点

  • 阅片时可关注照射侧与对侧乳腺的超声直方图差异,辅助客观评估放疗后急性乳腺毒性。
  • 下象限直方图参数对区分中度/重度毒性具有较高敏感度,但特异度中等,需结合B模式图像分级综合判断。

局限性

  • 研究为初步证据,样本量67例,需进一步验证。
  • 特异度范围0.53-0.83,部分时间点较低,可能存在假阳性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Accurate assessment of radiation-induced breast toxicity is crucial for the management of breast radiation therapy (RT). Standard assessment of breast toxicity based on clinicians' visual inspection and palpation has considerable inter- and intra-observer variability. To overcome this challenge, we present an ultrasound histogram method that objectively evaluates radiation-induced breast toxicity longitudinally. In a prospective study, patients enrolled (n = 67) received ultrasound scans at four time points: prior to RT, last day of RT, 3-4 wk post-RT and 9-12-wk post-RT. Ultrasound scans were acquired at five locations (tumor bed and 3, 6, 9 and 12 o'clock) on both breasts. Two hundred sixty-four ultrasound scans and 2640 B-mode images were analyzed. The histogram differences between irradiated and contralateral breasts were calculated to evaluate radiation-induced breast changes. On the basis of the B-mode images, the severity of breast toxicity was graded as absent, mild, moderate or severe. The performance of the histogram method was assessed with the receiver operating characteristic (ROC) curve. The areas under the ROC curve ranged from 0.78 to 0.9 (sensitivity: 0.88-0.96, specificity: 0.53-0.83) at the lower quadrant for differentiating absent/mild from moderate/severe toxicity at various time points. This study provides preliminary evidence that ultrasound histogram differences can serve as an imaging biomarker to longitudinally assess radiation-induced acute toxicity.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zhou, Wang, Yang, et al. Ultrasound Histogram Assessment of Acute Breast Toxicity After Breast Cancer Radiation Therapy: A Prospective Longitudinal Study. Ultrasound Med Biol. 2022. PMID: 36441032. doi:10.1016/j.ultrasmedbio.2022.09.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。