文献速递外周血管USCT

腹主动脉瘤三维多视角超声图像的时空配准

Spatiotemporal Registration of 3-D Multi-perspective Ultrasound Images of Abdominal Aortic Aneurysms.
PubMed 文献 · Ultrasound Med Biol · 2022-10-26

本文提出一种提升腹主动脉瘤三维超声时间分辨率和视野的方法:通过将多个血流脉冲周期排序为一个周期来提高帧率,并对多视角采集进行时间配准,再利用基于图像特征的相位相关和小波变换进行空间配准融合。在体模中时间排序完全正确,62例患者中51例成功,帧率提高5倍;空间配准在37例中32例成功,融合超声与CT分割的95百分位Hausdorff距离为4.2±1.7 mm,相似指数为0.92±0.02,视野扩大9%-49%。

要点

  • 多视角三维超声时空配准可提高腹主动脉瘤监测的帧率和视野
  • 时间排序利用脉搏波速率将多周期数据合成,帧率提升5倍
  • 空间融合与CT分割比较,95百分位Hausdorff距离4.2±1.7 mm,相似指数0.92±0.02

诊断标准与关键数值

  • 时间排序在体模中完全正确,在62例患者中51例成功,帧率提高5倍。
  • 空间配准在37例患者中32例成功,融合超声与CT分割的95百分位Hausdorff距离为4.2±1.7 mm,相似指数为0.92±0.02。
  • 融合后视野扩大9%-49%。

临床应用与阅片要点

  • 可利用多视角采集和时空配准扩大腹主动脉瘤超声视野并提高时间分辨率。
  • 空间配准成功性需与CT分割对比验证,注意配准误差(95百分位Hausdorff距离约4.2 mm)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Methods for patient-specific abdominal aortic aneurysm (AAA) progression monitoring and rupture risk assessment are widely investigated. Three-dimensional ultrasound can visualize the AAA's complex geometry and displacement fields. However, ultrasound has a limited field of view and low frame rate (i.e., 3-8 Hz). This article describes an approach to enhance the temporal resolution and the field of view. First, the frame rate was increased for each data set by sequencing multiple blood pulse cycles into one cycle. The sequencing method uses the original frame rate and the estimated pulse wave rate obtained from AAA distension curves. Second, the temporal registration was applied to multi-perspective acquisitions of the same AAA. Third, the field of view was increased through spatial registration and fusion using an image feature-based phase-only correlation method and a wavelet transform, respectively. Temporal sequencing was fully correct in aortic phantoms and was successful in 51 of 62 AAA patients, yielding a factor 5 frame rate increase. Spatial registration of proximal and distal ultrasound acquisitions was successful in 32 of 37 different AAA patients, based on the comparison between the fused ultrasound and computed tomography segmentation (95th percentile Haussdorf distances and similarity indices of 4.2 ± 1.7 mm and 0.92 ± 0.02 mm, respectively). Furthermore, the field of view was enlarged by 9%-49%.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Sjoerdsma, Verstraeten, Maas, et al. Spatiotemporal Registration of 3-D Multi-perspective Ultrasound Images of Abdominal Aortic Aneurysms. Ultrasound Med Biol. 2022. PMID: 36441033. doi:10.1016/j.ultrasmedbio.2022.09.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。