三维超声在肩袖撕裂形态学评估中的临床价值:一项前瞻性研究
前瞻性纳入52例肩袖撕裂患者,以关节镜为参考标准,比较三维超声与MRI评估撕裂形态的准确性。三维超声总体诊断准确率82.7%,显著高于MRI的57.7%(p=0.008),且两位医师间一致性良好(κ=0.709),重建与评估耗时<5分钟。三维超声可用于肩袖撕裂术前分型,辅助选择修复技术。
要点
- 三维超声评估肩袖撕裂形态的总体准确率显著优于MRI。
- 三维超声对新月形、前L形、后L形、T形撕裂的准确率均高于MRI。
- 三维超声检查耗时短(<5分钟),医师间一致性良好。
核心结论
- 三维超声可用于肩袖撕裂的术前形态学评估,有助于正确选择手术修复技术。
研究设计与样本
- 前瞻性研究,纳入52例患者(52个肩关节),两位放射科医师分别用三维超声和MRI评估撕裂形态,以关节镜为参考标准计算诊断准确率。
诊断标准与关键数值
- 三维超声评估肩袖撕裂形态的总体准确率为82.7%(43/52;95% CI:72.1-93.3%),显著高于MRI的57.7%(31/52;95% CI:45.8-73.4%)(p=0.008)。
- 三维超声与MRI各型撕裂准确率比较:新月形95.0% vs. 55.0%,前L形83.3% vs. 77.8%,后L形50.0% vs. 25.0%,T形75.0% vs. 0.0%,巨大撕裂80.0% vs. 100.0%。
- 两位医师用三维超声评估的准确率分别为84.6%(44/52)和76.9%(40/52),一致性为κ=0.709。
临床应用与阅片要点
- 阅片时可按新月形、前L形、后L形、T形、U形和巨大撕裂进行分型,前L形和后L形为本文首次用于描述肩袖撕裂形态。
- 三维超声重建与评估耗时<5分钟,可作为术前评估肩袖撕裂形态的便捷工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To study the clinical value of three-dimensional ultrasonography (3D-US) in the morphological evaluation of rotator cuff tears (RCTs).
METHODS: Based on previously published literature, RCT patterns in our study were divided into crescent, L-shaped with the remnant tendon retracted to the anterior rotator cuff (aL-shaped), L-shaped with the remnant tendon retracted to the posterior rotator cuff (pL-shaped), T-shaped (a tear pattern that is a combination of aL-shaped and pL-shaped), U-shaped, and massive type. Two radiologists prospectively assessed the tear patterns using 3D-US as well as magnetic resonance imaging (MRI) and compared these results using arthroscopy to calculate diagnostic accuracy.
RESULT: Fifty-two patients (52 shoulders) were enrolled. The overall diagnostic accuracy of 3D-US in evaluating RCT patterns (82.7%, 43/52; 95% CI: 72.1-93.3%) was significantly higher (p = 0.008) than that of the MRI (57.7%, 31/52; 95% CI: 45.8-73.4%). The accuracy of 3D-US was higher than that of MRI for most types of tears (crescent: 95.0% vs. 55.0%, aL-shaped: 83.3% vs. 77.8%, pL-shaped: 50.0% vs. 25.0%, T-shaped: 75.0% vs. 0.0%, and massive type: 80.0% vs. 100.0%). The accuracies of 3D-US with respect to evaluation by the two radiologists were 84.6% (44/52) and 76.9% (40/52), and there was substantial agreement evident (κ = 0.709). The time taken by the two radiologists to reconstruct the 3D-US images and evaluate the tear pattern was < 5 min.
CONCLUSION: The 3D-US can be used for the preoperative evaluation of RCT patterns, and thus be useful for the correct selection of the surgical repair technique for RCTs.
KEY POINTS: • Few studies have been found exploring the value of 3D-US for the morphological evaluation of RCTs and correlated with the arthroscopic findings. • Based on previous studies on the morphological classification, anterior L shape (aL-shaped), and posterior L shape (pL-shaped) were used for the first time to describe the torn patterns of RCT.
引用
- Chen, Wang, Chen, et al. Clinical value of three-dimensional ultrasonography in the morphologic evaluation of rotator cuff tear: a prospective study. Eur Radiol. 2022. PMID: 36418625. doi:10.1007/s00330-022-09213-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。