MRI衍生肝脏表面结节性评分的可重复性:不同扫描仪重复MRI分析
LSN评分存在区域差异(右后>右前>左前,p<0.001),跨扫描仪可重复性高至优秀(ICC=0.838-0.921),LSN与MR弹性成像肝硬度值呈低至中度相关(r=0.364-0.592)。
要点
- 肝表面结节性评分存在区域差异,右后最高、左前最低。
- 不同MRI扫描仪间LSN测量可重复性高至优秀(ICC=0.838-0.921)。
- LSN评分与肝硬度值相关性低至中度,慢性乙肝组高于非慢性乙肝组。
关键影像表现/征象
- LSN评分从高到低依次为右后、右前、左前,代表区域差异(p<0.001)。
- 不同MRI扫描仪间LSN测量可重复性高至优秀(ICC=0.838-0.921)。
- 两次检查在所有肝区域高度相关(r=0.712-0.839,p<0.001)。
诊断标准与关键数值
- 跨扫描仪可重复性ICC=0.838-0.921。
- LSN评分与肝硬度值相关性r=0.364-0.592(p≤0.001),慢性乙肝组高于非慢性乙肝组。
- 读者1两次检查平均差异:右前0.032(p=0.013)、右后0.002(p=0.910)、左前0.010(p=0.285)。
- 读者2两次检查平均差异:右前0.051(p=0.004)、右后0.061(p=0.002)、左前0.023(p=0.005)。
临床应用与阅片要点
- 测量LSN评分时需注意肝区域差异,右后区域评分最高。
- 不同扫描仪间LSN评分可重复性良好,可用于纵向随访。
- LSN评分与肝硬度值相关性低至中度,不能完全替代弹性成像。
局限性
- 回顾性研究设计。
- 未标准化量化软件和肝区域选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess trans-regional differences, reproducibility across different MRI scanners, and interobserver agreement of liver surface nodularity (LSN) score from routine liver MRI and to evaluate the correlation between LSN score and liver stiffness (LS) value on MR elastography.
MATERIALS AND METHODS: Ninety patients who underwent gadoxetic acid-enhanced liver MRI twice using different MRI scanners within a year were evaluated. On axial hepatobiliary phase images, right anterior (LSNRT_ANT), right posterior (LSNRT_POST), and left anterior hepatic surface (LSNLT) were chosen for the quantification of LSN score. Repeated-measures ANOVA, paired t test, Pearson's correlation coefficient analysis, and intraclass correlation coefficient (ICC) were used for statistical analysis.
RESULTS: LSN scores from high to low were LSNRT_POST, LSNRT_ANT, and LSNLT, representing trans-regional differences (p < 0.001). Reproducibility of LSN measurement across different MRI scanners was high to excellent (ICC = 0.838-0.921). The mean difference between first and second examinations in LSNRT_ANT, LSNRT_POST, and LSNLT were 0.032 (p = 0.013), 0.002 (p = 0.910), and 0.010 (p = 0.285) for reader 1 and 0.051 (p = 0.004), 0.061 (p = 0.002), and 0.023 (p = 0.005) for reader 2. The first and second examinations were highly correlated in all hepatic regions (r = 0.712-0.839, p < 0.001). There was a low to moderate correlation between LSN score and LS value (r = 0.364-0.592, p ≤ 0.001), which was higher in the chronic hepatitis B (CHB) group than in the non-CHB group in all hepatic regions.
CONCLUSIONS: In our study, LSN measurement on liver MRI showed trans-regional differences and excellent reproducibility across different MRI scanners. To use LSN score more widely, standardization of quantification software and selected hepatic regions is needed.
引用
- Bae, Yang, Park, et al. Reproducibility of MRI-derived liver surface nodularity score: analysis of patients with repeated MRI in various scanners. Abdom Radiol (NY). 2022. PMID: 36416904. doi:10.1007/s00261-022-03744-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。