超灵敏超声微血管成像评估肝硬化大鼠肝脏微循环
本研究在5只肝硬化和5只对照Sprague-Dawley大鼠中,通过剖腹术使用超灵敏超声微血管成像(UMI)在体成像肝脏微血管,并与常规能量多普勒超声和离体微CT比较。UMI可检测肝包膜下微小血管,肝硬化组血管密度和FMBV较低、SOAM较高,且与病理血管密度及肝组织缺氧相关。结论:无造影剂UMI可无创在体定量评估肝硬化肝脏微血管。
要点
- UMI可检测常规能量多普勒和微CT难以显示的肝包膜下微小血管。
- 肝硬化组血管密度和FMBV降低、SOAM升高,提示灌注减少和迂曲度增加。
- UMI定量参数与病理血管密度和肝组织缺氧相关,可用于无创评估肝微循环。
关键影像表现/征象
- UMI较常规能量多普勒超声和微CT更能检测肝包膜下微小血管。
临床应用与阅片要点
- UMI可无创定量肝微血管灌注和迂曲度,辅助评估肝硬化微循环改变。
- 血管密度、FMBV和SOAM与病理血管密度及缺氧相关,可作为微循环评估指标。
局限性
- 样本量小(肝硬化5只、对照5只),为动物实验,临床转化需进一步验证。
- UMI通过剖腹术进行,非完全无创经皮检查。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Liver microcirculation dysfunction plays a vital role in the occurrence and development of liver diseases, and thus, there is a clinical need for in vivo, noninvasive, and quantitative evaluation of liver microcirculation. Purpose To evaluate the feasibility of ultrasensitive US microvessel imaging (UMI) in the visualization and quantification of hepatic microvessels in healthy and cirrhotic rats. Materials and Methods In vivo studies were performed to image hepatic microvasculature by means of laparotomy in Sprague-Dawley rats (five cirrhotic and five control rats). In vivo conventional power Doppler US and ex vivo micro-CT were performed for comparison. UMI-based quantifications of perfusion, tortuosity, and integrity of microvessels were compared between the control and cirrhotic groups by using the Wilcoxon test. Spearman correlations between quantification parameters and pathologic fibrosis, perfusion function, and hepatic hypoxia were evaluated. Results UMI helped detect minute vessels below the liver capsule, as compared with conventional power Doppler US and micro-CT. With use of UMI, lower perfusion indicated by vessel density (median, 22% [IQR, 20%-28%] vs 41% [IQR, 37%-46%]; P = .008) and fractional moving blood volume (FMBV) (median, 6.4% [IQR, 4.8%-8.6%] vs 13% [IQR, 12%-14%]; P = .008) and higher tortuosity indicated by the sum of angles metric (SOAM) (median, 3.0 [IQR, 2.9-3.0] vs 2.7 [IQR, 2.6-2.9]; P = .008) were demonstrated in the cirrhotic rat group compared with the control group. Vessel density (r = 0.85, P = .003), FMBV (r = 0.86, P = .002), and median SOAM (r = -0.83, P = .003) showed strong correlations with pathologically derived vessel density labeled with dextran. Vessel density (r = -0.81, P = .005) and median SOAM (r = 0.87, P = .001) also showed strong correlations with hepatic tissue hypoxia. Conclusion Contrast-free ultrasensitive US microvessel imaging provided noninvasive in vivo imaging and quantification of hepatic microvessels in cirrhotic rat liver. © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Fetzer in this issue.
引用
- Zhang, Huang, Yin, et al. Ultrasensitive US Microvessel Imaging of Hepatic Microcirculation in the Cirrhotic Rat Liver. Radiology. 2022. PMID: 36413130. doi:10.1148/radiol.220739
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。