文献速递胸部技术与安全CT

基于定位像的深度学习计算患者体型与衰减替代指标:面向个体化胸部CT协议优化

Deep Learning-based calculation of patient size and attenuation surrogates from localizer Image: Toward personalized chest CT protocol optimization.
PubMed 文献 · Eur J Radiol · 2022-11-11

研究收集4005例患者的三维胸部CT和二维定位像,训练改进U-NET从定位像预测三维CT,在648例和138例外部队列测试。预测与真实图像体轮廓的SSIM为0.998±0.001,Dice为0.950±0.016,水当量直径平均百分比误差为2.7±3.5%,较大患者误差更显著。模型对检查床高度变化稳健,有助于患者剂量降低和协议优化。

要点

  • 定位像深度学习可逐层预测患者体型、形状和衰减参数,无需厂商特定校准。
  • 水当量直径计算平均百分比误差2.7±3.5%,较大患者误差更明显。
  • 模型对检查床高度变化稳健,可用于扫描前剂量估算和协议优化。

关键影像表现/征象

  • 预测与真实图像体轮廓的SSIM为0.998±0.001,Dice为0.950±0.016。
  • 水当量直径平均百分比误差为2.7±3.5%,较大患者误差更显著(P<0.05)。
  • 外部队列138例原始轴位图像测得的DW、管电流和CTDIvol显著大于648例外部队列(P<0.05)。

诊断标准与关键数值

  • 水当量直径(DW)平均百分比误差2.7±3.5%,较大患者误差更显著(P<0.05)。
  • 体轮廓SSIM为0.998±0.001,Dice指数为0.950±0.016。

临床应用与阅片要点

  • 可在螺旋扫描前从定位像逐层估算患者体型和衰减参数,用于个体化剂量估算和协议优化。
  • 模型对检查床高度变化稳健,但较大患者的水当量直径计算误差更明显,需注意。

局限性

  • 水当量直径计算误差在较大患者中更显著。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Extracting water equivalent diameter (DW), as a good descriptor of patient size, from the CT localizer before the spiral scan not only minimizes truncation errors due to the limited scan field-of-view but also enables prior size-specific dose estimation as well as scan protocol optimization. This study proposed a unified methodology to measure patient size, shape, and attenuation parameters from a 2D anterior-posterior localizer image using deep learning algorithms without the need for labor-intensive vendor-specific calibration procedures.

METHODS: 3D CT chest images and 2D localizers were collected for 4005 patients. A modified U-NET architecture was trained to predict the 3D CT images from their corresponding localizer scans. The algorithm was tested on 648 and 138 external cases with fixed and variable table height positions. To evaluate the performance of the prediction model, structural similarity index measure (SSIM), body area, body contour, Dice index, and water equivalent diameter (DW) were calculated and compared between the predicted 3D CT images and the ground truth (GT) images in a slicewise manner.

RESULTS: The average age of the patients included in this study (1827 male and 1554 female) was 53.8 ± 17.9 (18-120) years. The DW, tube current ,and CTDIvol measured on original axial images in the external 138 cases group were significantly larger than those of the external 648 cases (P < 0.05). The SSIM and Dice index calculated between the prediction and GT for body contour were 0.998 ± 0.001 and 0.950 ± 0.016, respectively. The average percentage error in the calculation of DW was 2.7 ± 3.5 %. The error in the DW calculation was more considerable in larger patients (p-value < 0.05).

CONCLUSIONS: We developed a model to predict the patient size, shape, and attenuation factors slice-by-slice prior to spiral scanning. The model exhibited remarkable robustness to table height variations. The estimated parameters are helpful for patient dose reduction and protocol optimization.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Salimi, Shiri, Akhavanallaf, et al. Deep Learning-based calculation of patient size and attenuation surrogates from localizer Image: Toward personalized chest CT protocol optimization. Eur J Radiol. 2022. PMID: 36410091. doi:10.1016/j.ejrad.2022.110602

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。