文献速递神经外周血管技术与安全US

健康老年人不同颞窗经颅多普勒扫描脑动脉的成功率

Success Rate of Transcranial Doppler Scanning of Cerebral Arteries at Different Transtemporal Windows in Healthy Elderly Individuals.
PubMed 文献 · Ultrasound Med Biol · 2022-11-15

研究纳入396名健康老年人,评估经颅多普勒在颞中窗、颞后窗和颞前窗探测脑动脉的成功率。结果显示81.1%的受试者至少有一个可穿透的颞窗,颞中窗成功率最高(72.2%),其次为颞后窗(49.2%)和颞前窗(26.8%),男性及较年轻者成功率更高,建议老年人首选颞中窗扫描。

要点

  • 健康老年人中约81.1%至少有一个可穿透的颞窗,颞中窗成功率最高(72.2%)。
  • 建议老年人经颅多普勒扫描时首选颞中窗,若选两个窗则推荐颞中窗和颞后窗。
  • 男性及较年轻者三个颞窗扫描成功率均更高,颞中窗还受两侧耳屏间弧长影响。

核心结论

  • 健康老年人中81.1%至少有一个颞窗可被经颅多普勒穿透,颞中窗成功率最高。
  • 建议老年人经颅多普勒扫描脑动脉时首选颞中窗定位,若使用两个颞窗则推荐颞中窗和颞后窗。
  • 男性及较年轻者三个颞窗扫描成功率均更高,颞中窗成功率随两侧耳屏间弧长减小而增加。

研究设计与样本

  • 研究类型为横断面观察性研究,纳入396名健康老年人(年龄62.6±6.0岁,男性140名)。
  • 使用手持1.6 MHz脉冲波经颅多普勒探头在颞中窗、颞后窗和颞前窗搜寻脑动脉。
  • 同时测量头围及两侧耳屏间弧长,采用回归分析探索与扫描成功率的关联。

诊断标准与关键数值

  • 至少一个颞窗可穿透的总体成功率为81.1%(321/396)。
  • 颞中窗成功率72.2%(286/396),颞后窗49.2%(195/396),颞前窗26.8%(106/396)。

临床应用与阅片要点

  • 老年患者经颅多普勒检查时优先选择颞中窗作为初始探测位置。
  • 若需使用两个颞窗,推荐颞中窗联合颞后窗,避免优先选择颞前窗。
  • 男性及较年轻患者颞窗穿透性更好,两侧耳屏间弧长较小者颞中窗成功率更高。

局限性

  • 研究仅纳入健康老年人,结论不能直接推广至其他年龄或患病人群。
  • 未报告操作者间一致性及重复测量数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study measured the rates of success in applying transcranial Doppler (TCD) scanning at the middle, posterior and anterior temporal windows (MTW, PTW and ATW) in the elderly. A hand-held 1.6-MHz pulsed-wave TCD transducer was used to search for cerebral arteries at MTW, PTW and ATW locations. Physical attributes of the head, including head circumference and the distance between tragi on both sides ("tragus-to-tragus arc length"), were also measured to explore the associations with successful rates. Among 396 healthy elderly participants (aged 62.6 ± 6.0 y, 140 men), 81.1% (n = 321; 127 men) had one or more temporal windows penetrable by TCD ultrasound (n = 286 [72.2%] at MTW, n = 195 [49.2%] at PTW and n = 106 [26.8%] at ATW). Regression analysis revealed that successful scanning increased significantly in male participants at three window locations. Younger age significantly increased successful scanning at the MTW and ATW. Smaller tragus-to-tragus arc length increased successful scanning at the MTW, but unsuccessful scanning at the ATW. Our findings support using MTW as the first location when positioning the TCD transducer for the scanning of cerebral arteries in the elderly population. When performing TCD scanning on two temporal windows, we propose choosing the MTW and PTW.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Chan, Ling, Chen, et al. Success Rate of Transcranial Doppler Scanning of Cerebral Arteries at Different Transtemporal Windows in Healthy Elderly Individuals. Ultrasound Med Biol. 2022. PMID: 36400675. doi:10.1016/j.ultrasmedbio.2022.10.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。