文献速递乳腺MR

深度学习模拟浸润性乳腺癌的增强乳腺MRI

Deep Learning to Simulate Contrast-enhanced Breast MRI of Invasive Breast Cancer.
PubMed 文献 · Radiology · 2022-11-15

本研究回顾性纳入96例经活检证实的浸润性乳腺癌女性,利用三维全卷积深度神经网络从5个平扫序列模拟增强T1加权乳腺MRI。模拟与真实增强MRI在肿瘤大小、强化区域和图像质量上具有良好一致性,95%模拟图像达诊断质量。

要点

  • 深度学习可从平扫MRI序列生成模拟增强图像,肿瘤强化可见且图像质量达诊断水平。
  • 模拟与真实增强MRI的肿瘤最大径一致性好(ICC 0.73-0.86),平均差异-0.8至0.8 mm。
  • 模拟图像强化肿瘤重叠的Dice系数为0.75±0.25,结构相似指数0.88±0.05。

关键影像表现/征象

  • 所有模拟MRI扫描被读者评估为具有真实MRI扫描的外观并可见肿瘤强化。
  • 模拟与真实MRI的指数肿块大小一致性好至优秀(ICC 0.73-0.86,P < .001),平均差异-0.8至0.8 mm(P = .36-.80)。
  • 84/88(95%)的模拟MRI扫描被认为具有诊断质量(优秀、可接受或良好)。
  • 定量分析显示强相似性(结构相似指数0.88±0.05)、低体素误差(对称平均绝对百分比误差3.26%)和强化肿瘤重叠Dice系数0.75±0.25。

诊断标准与关键数值

  • 图像质量评估等级:优秀、可接受、良好、差、不可接受;诊断质量定义为优秀、可接受或良好。
  • 肿瘤大小一致性:组内相关系数(ICC)0.73-0.86,P < .001;平均差异-0.8至0.8 mm,P = .36-.80。
  • 定量指标:结构相似指数0.88±0.05;对称平均绝对百分比误差3.26%;强化肿瘤重叠Dice系数0.75±0.25。

临床应用与阅片要点

  • 模拟增强图像可作为非增强乳腺MRI的替代方案,用于肿瘤可视化和大小评估。
  • 阅片时需注意模拟图像虽具真实增强外观,但仍需结合原始平扫序列综合判断。
  • 肿瘤大小测量在模拟与真实图像间差异小,但个体层面仍需谨慎。

局限性

  • 单中心回顾性研究,样本量有限(96例)。
  • 仅纳入经活检证实的浸润性乳腺癌,未涵盖其他乳腺病变。
  • 定性评估仅使用22对真实与模拟图像。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background There is increasing interest in noncontrast breast MRI alternatives for tumor visualization to increase the accessibility of breast MRI. Purpose To evaluate the feasibility and accuracy of generating simulated contrast-enhanced T1-weighted breast MRI scans from precontrast MRI sequences in biopsy-proven invasive breast cancer with use of deep learning. Materials and Methods Women with invasive breast cancer and a contrast-enhanced breast MRI examination that was performed for initial evaluation of the extent of disease between January 2015 and December 2019 at a single academic institution were retrospectively identified. A three-dimensional, fully convolutional deep neural network simulated contrast-enhanced T1-weighted breast MRI scans from five precontrast sequences (T1-weighted non-fat-suppressed [FS], T1-weighted FS, T2-weighted FS, apparent diffusion coefficient, and diffusion-weighted imaging). For qualitative assessment, four breast radiologists (with 3-15 years of experience) blinded to whether the method of contrast was real or simulated assessed image quality (excellent, acceptable, good, poor, or unacceptable), presence of tumor enhancement, and maximum index mass size by using 22 pairs of real and simulated contrast-enhanced MRI scans. Quantitative comparison was performed using whole-breast similarity and error metrics and Dice coefficient analysis of enhancing tumor overlap. Results Ninety-six MRI examinations in 96 women (mean age, 52 years ± 12 [SD]) were evaluated. The readers assessed all simulated MRI scans as having the appearance of a real MRI scan with tumor enhancement. Index mass sizes on real and simulated MRI scans demonstrated good to excellent agreement (intraclass correlation coefficient, 0.73-0.86; P < .001) without significant differences (mean differences, -0.8 to 0.8 mm; P = .36-.80). Almost all simulated MRI scans (84 of 88 [95%]) were considered of diagnostic quality (ratings of excellent, acceptable, or good). Quantitative analysis demonstrated strong similarity (structural similarity index, 0.88 ± 0.05), low voxel-wise error (symmetric mean absolute percent error, 3.26%), and Dice coefficient of enhancing tumor overlap of 0.75 ± 0.25. Conclusion It is feasible to generate simulated contrast-enhanced breast MRI scans with use of deep learning. Simulated and real contrast-enhanced MRI scans demonstrated comparable tumor sizes, areas of tumor enhancement, and image quality without significant qualitative or quantitative differences. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Slanetz in this issue. An earlier incorrect version appeared online. This article was corrected on January 17, 2023.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Chung, Calabrese, Mongan, et al. Deep Learning to Simulate Contrast-enhanced Breast MRI of Invasive Breast Cancer. Radiology. 2022. PMID: 36378030. doi:10.1148/radiol.213199

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。