双能CT虚拟去钙与Rho/Z图对原发性恶性骨肿瘤骨髓浸润的诊断价值
回顾性分析65例原发性恶性骨肿瘤患者,评估双能CT虚拟去钙(VNCa)与Rho/Z图诊断骨髓浸润的效能,以MRI为参考标准。VNCa和Rho/Z图的准确率(91%、92%)和敏感度(90%、92%)均高于常规CT(67%、69%)。VNCa与Rho/Z的曲线下面积分别为0.995和0.988,截断值分别为-31.57 HU和7.8,两者敏感度均为96.9%。
要点
- VNCa和Rho/Z图诊断骨髓浸润的敏感度与准确率均优于常规CT图像。
- VNCa图骨髓浸润区CT值截断值为-31.57 HU,Rho/Z图Zeff截断值为7.8。
- VNCa与Rho/Z图对肿瘤浸润范围的纵向和横向直径测量与MRI存在差异。
关键影像表现/征象
- VNCa和Rho/Z图诊断骨髓浸润的准确率分别为91%和92%,常规CT为67%。
- VNCa和Rho/Z图诊断骨髓浸润的敏感度分别为90%和92%,常规CT为69%。
- VNCa与Rho/Z图测量肿瘤浸润最大纵径与常规CT、MRI存在统计学差异。
- 常规CT、VNCa、Rho/Z图测量最大横径与MRI存在统计学差异。
- 正常与浸润骨髓区的VNCa图CT值和Rho/Z图Zeff值差异均有统计学意义(p<0.001)。
诊断标准与关键数值
- VNCa图诊断骨髓浸润的AUC为0.995,截断值-31.57 HU,敏感度96.9%。
- Rho/Z图诊断骨髓浸润的AUC为0.988,截断值7.8,敏感度96.9%。
临床应用与阅片要点
- 在常规CT怀疑骨髓浸润时,可结合VNCa和Rho/Z图提高检出敏感度。
- 测量VNCa图CT值(截断值-31.57 HU)和Rho/Z图Zeff值(截断值7.8)辅助判断骨髓浸润。
- 注意VNCa和Rho/Z图测量的肿瘤浸润范围与MRI存在差异,报告范围时需谨慎。
局限性
- 回顾性研究,样本量65例,可能存在选择偏倚。
- 单中心研究,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: We investigated the diagnostic performance of dual-energy CT (DECT) virtual non-calcium (VNCa) and Rho/Z images for bone marrow infiltration of primary malignant bone tumors (PMBTs).
MATERIALS AND METHODS: We retrospectively analyzed 65 patients with PMBT who underwent DECT and MRI within 2 weeks. DECT was used to evaluate the presence and extent of marrow involvement surrounding PMBTs using the SCT, VNCa, and Rho/Z images. MRI was used as the reference standard for measurements. CT values of normal and involved bone marrow areas were measured on VNCa images, and Zeff values were measured on Rho/Z images. The statistical methods used were the 2*C chi-square test, ANOVA test, paired samples t test, and diagnostic performance of the different variables were evaluated using receiver operating characteristic curves.
RESULTS: VNCa and Rho/Z images showed higher accuracy (91%, 92% vs. 67%) and sensitivity (90%, 92% vs. 69%) than SCT images for diagnosing bone marrow infiltration in patients with PMBT. The maximum longitudinal diameter of tumor involvement measurements was statistically different between VNCa and SCT, Rho/Z and SCT, MRI, and SCT (all p < 0.05, p = 0.047, p = 0.049, and p = 0.023, respectively). The maximum transverse diameter was statistically significant between SCT and MRI, VNCa and MRI, Rho/Z and MRI (all p < 0.05, and p = 0.015, and p = 0.044, and p = 0.047, respectively). The HU or Zeff values based on the area of interest of VNCa and Rho/Z images differed significantly between the normal and infiltrated bone marrow area (p < 0.001). Receiver operating characteristic curve analysis revealed area under the curves of 0.995 and 0.988, respectively, with cut-off values of -31.57 HU and 7.8, and the sensitivity of both was 96.9%.
CONCLUSION: DECT-VNCa and Rho/Z images have good diagnostic value when evaluating bone marrow infiltration in PMBTs.
引用
- Liu, Pan, Wu, et al. Diagnostic Value of Dual-Energy CT Virtual Non-Calcium and Rho/Z Images for Bone Marrow Infiltration in Primary Malignant Bone Tumors. Acad Radiol. 2022. PMID: 36371375. doi:10.1016/j.acra.2022.10.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。