基于18F-FDG PET/CT的影像组学列线图术前预测巨梁块型-巨块型肝细胞癌:一项双中心研究
本研究纳入两个中心共140例术前接受18F-FDG PET/CT检查的肝细胞癌患者,提取影像组学特征并计算Rad-score,结合临床特征及肿瘤FDG代谢指标TLR构建列线图。多因素分析显示Rad-score、年龄≤50岁、AST>40U/L及TLR为MTM-HCC的独立预测因子,列线图在训练集和验证集的AUC分别为0.849和0.749,均高于Rad-score及TLR,DCA显示列线图临床有用性更优。
要点
- 18F-FDG PET/CT影像组学列线图可用于术前预测MTM-HCC亚型。
- 列线图预测效能优于单一Rad-score或TLR,训练集AUC 0.849。
- TLR、Rad-score、年龄≤50岁及AST>40U/L为独立预测因子。
局限性
- 回顾性研究设计。
- 样本量有限(共140例,验证集仅39例)。
- 仅基于两中心数据,需外部验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To explore the potential of β-2-[18F] fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) in the evaluation of macrotrabecular-massive (MTM) hepatocellular carcinoma (HCC) and to apply radiomics approach to build a radiomics nomogram for predicting MTM-HCC.
METHODS: This study included 140 (training cohort:101; validation cohort:39) HCC patients who underwent preoperative 18F-FDG PET/CT at two institutions. The clinical features and tumor FDG metabolism measured by the tumor-to-liver ratio (TLR) via 18F-FDG PET/CT were retrospectively collected. Radiomics features were extracted from 18F-FDG PET/CT images and a radiomics score (Rad-score) was calculated. A radiomics nomogram was then constructed by combining Rad-score and independent clinical features and was assessed with a calibration curve. The performance of the radiomics nomogram, Rad-score and TLR was evaluated by receiver operating characteristic (ROC) curves and decision curve analysis (DCA).
RESULTS: A total of six top weighted radiomics features were selected from PET/CT images by the least absolute shrinkage and selection operator (LASSO) regression algorithm and were used to construct a Rad-score. Multivariate analysis identified Rad-score (OR = 2.183, P = 0.004), age ≤ 50 years (OR = 3.136, P = 0.036), AST > 40U/L (OR = 0.270, P = 0.017) and TLR (OR = 1.641, P = 0.049) as independent predictors of MTM-HCC. The radiomics nomogram had a higher area under the curves (AUCs) than the Rad-score and TLR for predicting MTM-HCC in both training (0.849 [95% CI 0.774-0.924] vs. 0.764 [95% CI 0.669-0.843], 0.763 [95% CI 0.668-0.842]) and validation (0.749 [95% CI 0.584-0.873] vs. 0.690 [95% CI 0.522-0.828], 0.541 [95% CI 0.374-0.701]) cohorts. DCA showed the radiomics nomogram to be more clinically useful than Rad-score and TLR.
CONCLUSIONS: Tumor FDG metabolism is significantly associated with MTM-HCC. A 18F-FDG PET/CT-based radiomics nomogram may be useful for preoperatively predicting the MTM subtype in primary HCC patients, contributing to pretreatment decision-making.
引用
- Hu, Kang, Xie, et al. 18F-FDG PET/CT-based radiomics nomogram for preoperative prediction of macrotrabecular-massive hepatocellular carcinoma: a two-center study. Abdom Radiol (NY). 2022. PMID: 36370179. doi:10.1007/s00261-022-03722-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。