深度学习约束压缩感知重建的快速三维屏气MRCP图像质量研究
该前瞻性研究纳入102例在3.0 T行MRCP的患者,比较3D DL-CS-MRCP与3D CS-MRCP、3D GRASE-MRCP及2D MRCP的图像质量。结果显示3D DL-CS-MRCP的SNR和CNR优于其他三种方案,对二级肝内胆管及胰管远端显示优于3D CS-MRCP,但主胰管评估逊于2D MRCP。
要点
- 3D DL-CS-MRCP在SNR、CNR及整体图像质量上优于3D CS-MRCP和3D GRASE-MRCP。
- 3D DL-CS-MRCP对二级肝内胆管和胰管远端显示优于3D CS-MRCP。
- 与2D MRCP相比,3D DL-CS-MRCP主胰管评估较差,但左肝二级胆管显示更优。
核心结论
- 3D DL-CS-MRCP整体性能优于3D CS-MRCP和3D GRASE-MRCP,与2D MRCP相比整体图像质量相当但主胰管评估较差。
研究设计与样本
- 前瞻性纳入102例连续患者,在3.0 T设备上均行2D MRCP、3D GRASE-MRCP、3D CS-MRCP和3D DL-CS-MRCP四种序列检查。
- 由两名放射科医师独立采用五分法评估整体图像质量、背景抑制、伪影及胰胆管显示,并测量CBD的SNR、CBD与肝脏的CNR及胆管周围组织与CBD的对比率。
- 采用Friedman检验比较四种序列。
诊断标准与关键数值
- 3D DL-CS-MRCP的SNR和CNR值优于其他三种序列(均p < 0.05)。
- 3D DL-CS-MRCP对比率优于3D CS-MRCP和3D GRASE-MRCP(均p < 0.05)。
- 定性分析显示3D DL-CS-MRCP对二级肝内胆管和胰管远端的显示优于3D CS-MRCP(均p < 0.05)。
- 与2D MRCP相比,3D DL-CS-MRCP对左肝二级胆管显示更优,但主胰管评估较差(均p < 0.05)。
- 3D DL-CS-MRCP图像质量显著高于3D GRASE-MRCP。
临床应用与阅片要点
- 在需要快速屏气MRCP且关注肝内胆管分支显示时,可优先考虑3D DL-CS-MRCP。
- 若临床重点评估主胰管,3D DL-CS-MRCP可能不如2D MRCP,需结合2D序列或酌情补充。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the image quality of three-dimensional breath-hold magnetic resonance cholangiopancreatography with deep learning-based compressed sensing reconstruction (3D DL-CS-MRCP) to those of 3D breath-hold MRCP with compressed sensing (3D CS-MRCP), 3D breath-hold MRCP with gradient and spin-echo (3D GRASE-MRCP) and conventional 2D single-shot breath-hold MRCP (2D MRCP).
METHODS: In total, 102 consecutive patients who underwent MRCP at 3.0 T, including 2D MRCP, 3D GRASE-MRCP, 3D CS-MRCP, and 3D DL-CS-MRCP, were prospectively included. Two radiologists independently analyzed the overall image quality, background suppression, artifacts, and visualization of pancreaticobiliary ducts using a five-point scale. The signal-to-noise ratio (SNR) of the common bile duct (CBD), contrast-to-noise ratio (CNR) of the CBD and liver, and contrast ratio between the periductal tissue and CBD were measured. The Friedman test was performed to compare the four protocols.
RESULTS: 3D DL-CS-MRCP resulted in improved SNR and CNR values compared with those in the other three protocols, and better contrast ratio compared with that in 3D CS-MRCP and 3D GRASE-MRCP (all, p < 0.05). Qualitative image analysis showed that 3D DL-CS-MRCP had better performance for second-level intrahepatic ducts and distal main pancreatic ducts compared with 3D CS-MRCP (all, p < 0.05). Compared with 2D MRCP, 3D DL-CS-MRCP demonstrated better performance for the second-order left intrahepatic duct but was inferior in assessing the main pancreatic duct (all, p < 0.05). Moreover, the image quality was significantly higher in 3D DL-CS-MRCP than in 3D GRASE-MRCP.
CONCLUSION: 3D DL-CS-MRCP has superior performance compared with that of 3D CS-MRCP or 3D GRASE-MRCP. Deep learning reconstruction also provides a comparable image quality but with inferior main pancreatic duct compared with that revealed by 2D MRCP.
KEY POINTS: • 3D breath-hold MRCP with deep learning reconstruction (3D DL-CS-MRCP) demonstrated improved image quality compared with that of 3D MRCP with compressed sensing or GRASE. • Compared with 2D MRCP, 3D DL-CS-MRCP had superior performance in SNR and CNR, better visualization of the left second-level intrahepatic bile ducts, and comparable overall image quality, but an inferior main pancreatic duct.
引用
- Zhang, Peng, Xiao, et al. Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction. Eur Radiol. 2022. PMID: 36355200. doi:10.1007/s00330-022-09227-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。