文献速递骨肌CTDR

双机器人无龙门架锥形束CT在急性肘部创伤中的应用

Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma.
PubMed 文献 · Radiology · 2022-11-08

回顾性纳入23例因体位困难无法行常规MDCT的急性肘部创伤成人与儿童患者,比较无龙门架CBCT与X线摄影对骨折、关节面累及及多块骨折的诊断效能,以手术报告为参考标准。CBCT敏感度更高或相当,读者诊断信心显著提升。

要点

  • 对于体位困难的急性肘外伤患者,无龙门架CBCT可替代常规MDCT完成三维评估。
  • CBCT对骨折、关节面累及及多块骨折模式的敏感度均高于或等于X线摄影。
  • CBCT显著提高放射科医生诊断信心,且剂量参数DLP中位数70.9 mGy·cm。
英文原文(摘要)· 点击展开

Background Posttraumatic CT imaging of the elbow can be challenging when patient mobility is limited. Gantry-free cone-beam CT (CBCT) with a twin robotic radiography system offers greater degrees of positioning freedom for three-dimensional elbow scans over gantry-based multidetector CT (MDCT), but studies analyzing their clinical value remain lacking. Purpose To investigate the diagnostic performance of gantry-free CBCT versus two-dimensional radiography in adults and children with acute elbow trauma. Materials and Methods In a retrospective study, consecutive patients with elbow trauma and positioning difficulty in a gantry-based MDCT who underwent three-dimensional elbow imaging with a gantry-free CBCT after radiography were enrolled between January 2021 and April 2022 at a tertiary care university hospital. Imaging data sets were independently analyzed for fracture presence, articular involvement, and multi-fragment injuries by three radiologists. Diagnostic performance was calculated individually with surgical reports serving as the reference standard. Differences between radiography and CBCT were compared with the McNemar test. Diagnostic confidence was estimated subjectively by each reader, and results were compared with the Wilcoxon signed-rank test. Results Elbow examinations of 23 adults and children (mean age ± SD, 49 years ± 23; seven women) were included with individual assessment of humerus, radius, and ulna (69 bones; 36 fractured). Multi-fragmentary fracture patterns and involvement of articular surfaces were ascertained in 28 and 30 bones, respectively. CBCT allowed for similar or higher sensitivity compared with radiography in the assessment of fractures (range for three readers, 94%-100% vs 72%-81%; respectively, P ≤ .06-.008), articular surface involvement (90%-97% vs 73%-87%; P ≤ .25), and multi-fragmentary patterns (96%-96% vs 68%-75%; P ≤ .03). Readers' diagnostic confidence improved considerably with access to CBCT data sets versus radiographs (all P ≤ .001). For CBCT, the median dose-length product was 70.9 mGy · cm, and the volume CT dose index was 4.4 mGy. Conclusion In acute elbow injuries, gantry-free cone-beam CT enabled improved detection of fractures, articular involvement, and multi-fragmentary patterns compared with two-dimensional radiography. Published under a CC BY 4.0 license Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kunz, Schmalzl, Huflage, et al. Twin Robotic Gantry-Free Cone-Beam CT in Acute Elbow Trauma. Radiology. 2022. PMID: 36346312. doi:10.1148/radiol.221200

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。