文献速递妇产影像US

基于标准化超声标记的胎盘植入谱系疾病严重程度风险预测模型

A Risk-Prediction Model for Placenta Accreta Spectrum Severity From Standardized Ultrasound Markers.
PubMed 文献 · Ultrasound Med Biol · 2022-11-06

前瞻性队列纳入106例有剖宫产史且前置/低置胎盘的孕妇,用标准化表单记录超声标记,分娩时临床和病理评估胎盘植入谱系疾病(PAS)分级。仅含四个关键变量(清晰带消失、异常胎盘腔隙、胎盘膨出、膀胱壁中断)的logistic回归模型可可靠预测PAS存在及严重程度,乐观校正C指数为0.901。

要点

  • 四个超声标记(清晰带消失、异常胎盘腔隙、胎盘膨出、膀胱壁中断)可预测PAS存在及严重程度。
  • 模型乐观校正C指数0.901,提示高预测准确性。
  • 该模型首次基于新近标准化的超声征象定义和疾病定义构建。

核心结论

  • 仅含四个关键超声变量的简单模型可高精度预测PAS的存在及严重程度(正常、异常黏附、异常侵入)。

研究设计与样本

  • 前瞻性队列研究,纳入106例有剖宫产史且前壁低置胎盘或前置胎盘的孕妇。
  • 超声标记记录于标准化表单,分娩时通过临床和组织学评估PAS存在及FIGO分级。
  • 将与PAS有预测关系的标记纳入logistic回归模型。

关键影像表现/征象

  • 模型包含的四个关键超声变量为:清晰带消失、异常胎盘腔隙、胎盘膨出、膀胱壁中断。

诊断标准与关键数值

  • 模型预测PAS存在及严重程度的乐观校正C指数为0.901。
  • PAS分级依据FIGO分级,通过分娩时临床和组织学评估确定。

临床应用与阅片要点

  • 对有剖宫产史且前置/低置胎盘的孕妇,可依据四个标准化超声标记评估PAS风险及严重程度。
  • 阅片时需重点关注清晰带消失、异常胎盘腔隙、胎盘膨出和膀胱壁中断四个征象。

局限性

  • 样本量106例,来自单中心前瞻性队列。
  • 模型尚未进行外部验证,需在更大队列中前瞻性应用验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

We aimed to generate a model to predict the risk of a woman having normal, abnormally adherent (AAP) or abnormally invasive placentation (AIP) based on the presence of recently codified ultrasound (US) markers and disease definitions of placenta accreta spectrum (PAS). We recruited women with anterior low-lying placenta or placenta previa and a history of previous caesarean delivery to a prospective cohort study. US markers of abnormal placentation were recorded on a standardized pro forma. The presence and International Federation of Gynecology and Obstetrics grade of PAS was evaluated clinically and histologically at delivery. Markers demonstrating a predictive relationship to PAS were incorporated into a logistic regression model. A total of 106 women were included, of whom 42 (40%) were normal, 24 (23%) had AAP and 40 (38%) had AIP. A model including just four key variables (loss of clear zone, abnormal placental lacunae, placental bulge and bladder wall interruption) was shown to reliably predict presence and severity of PAS, with an optimism-corrected C-index of 0.901. A simple model incorporating four US markers can predict likelihood and severity of PAS with high accuracy. This is the first time this has been demonstrated using the recently codified definitions of the US signs and disease definitions. Further work will see our model applied prospectively to a large patient cohort, ideally through a smartphone-based application, for external validation.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Sargent, Gerry, Collins, et al. A Risk-Prediction Model for Placenta Accreta Spectrum Severity From Standardized Ultrasound Markers. Ultrasound Med Biol. 2022. PMID: 36347659. doi:10.1016/j.ultrasmedbio.2022.09.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。