文献速递神经MR

三成分多b值扩散加权成像可作为检测胶质瘤微结构特征的生物标志物

A three-component multi-b-value diffusion-weighted imaging might be a useful biomarker for detecting microstructural features in gliomas with differences in malignancy and IDH-1 mutation status.
PubMed 文献 · Eur Radiol · 2022-11-08

本研究纳入60例胶质瘤患者,采用三成分扩散模型获得中间扩散系数Dint、灌注相关扩散系数Dp及相应分数Fvery-slow、Fint、Fp,并与扩散峰度模型及单/双指数模型比较。结果显示Fint在区分低级别与高级别胶质瘤中AUC最高(0.872),且Fint和Fp在IDH-1突变型与野生型间有显著差异。三成分DWI模型有助于评估胶质瘤分级和IDH-1基因型。

要点

  • Fint在区分低级别与高级别胶质瘤中AUC达0.872,优于其他模型参数。
  • Fint和Fp在IDH-1突变型与野生型胶质瘤间差异显著(p=0.007和0.01)。
  • 多因素回归后Fint是唯一与胶质瘤分级独立相关的参数。

关键影像表现/征象

  • 高级别胶质瘤的Fint、Fvery-slow和Dp值显著高于低级别胶质瘤,而Fp和Dint值显著低于低级别胶质瘤。
  • Fint和Fp在II、III、IV级胶质瘤间差异显著(p<0.05)。

诊断标准与关键数值

  • Fint区分低级别与高级别胶质瘤的AUC为0.872。
  • Fint和Fp在IDH-1突变型与野生型胶质瘤间差异显著(p=0.007和0.01)。

临床应用与阅片要点

  • 三成分DWI模型参数Fint可作为评估胶质瘤分级和IDH-1基因型的影像生物标志物。
  • 多因素回归分析中Fint是唯一独立区分胶质瘤分级的参数,提示其潜在价值。

局限性

  • 样本量较小(60例),可能影响统计效能和结论普适性。
  • 单中心研究设计,需多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of the study was to explore the performance of a three-component diffusion model in evaluating the degree of malignancy and isocitrate dehydrogenase 1 (IDH-1) gene type of gliomas.

METHODS: Overall, 60 patients with gliomas were enrolled. The intermediate and perfusion-related diffusion coefficients (Dint and Dp) and fractions of strictly limited, intermediate, and perfusion-related diffusion (Fvery-slow, Fint, and Fp) were obtained with a three-component diffusion model. Parameters were also obtained from a diffusion kurtosis model and mono- and biexponential models. All parameters were compared between different tumor grades and IDH-1 gene types. Diagnostic performance and logistic regression analyses were performed.

RESULTS: High-grade gliomas (HGGs) had significantly higher Fint, Fvery-slow, and Dp values but significantly lower Fp and Dint values than low-grade gliomas (LGGs), and Fint and Fp differed significantly among grade II, III, and IV gliomas (p < 0.05 for all). Fint achieved the highest AUC of 0.872 in differentiating between LGGs and HGGs. Logistic regression analysis revealed that in each model, Fint, diffusion coefficient (D), apparent diffusion coefficient (ADC), mean diffusivity (MD), and mean kurtosis (MK) were associated with glioma grading. After multiple regression analysis, Fint remained the only differentiator. Additionally, Fint and Fp showed significant differences between IDH-1 mutated and IDH-1 wild-type gliomas (p = 0.007 and 0.01, respectively).

CONCLUSIONS: The three-component DWI model served as a useful biomarker for detecting microstructural features in gliomas with different grades and IDH-1 mutation statuses.

KEY POINTS: • The three-component model enables the estimation of an intermediate diffusion component. • The three-component model performed better than the other models in glioma grading and genotyping. • Fint was useful in evaluating the grade and genotype of gliomas.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Cao, Wang, Liu, et al. A three-component multi-b-value diffusion-weighted imaging might be a useful biomarker for detecting microstructural features in gliomas with differences in malignancy and IDH-1 mutation status. Eur Radiol. 2022. PMID: 36346441. doi:10.1007/s00330-022-09212-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。