便携式低场强MRI的定量脑形态学:超分辨率机器学习算法
本研究开发并验证了一种超分辨率卷积神经网络,可将0.064T便携式低场强脑MRI的T1/T2加权图像合成为1mm各向同性高分辨率图像,从而适用于自动定量脑形态学分析。
要点
- 低场强便携MRI直接分割与高场强定量形态学相关性差,超分辨率合成后显著改善。
- 合成图像上所有ROI相关性均显著,海马r=0.85、丘脑r=0.84、全脑r=0.92。
- z score偏差图与病理异常视觉相关,提示合成图像可用于检出异常。
关键影像表现/征象
- 直接分割低场强MRI与高场强体积测量在多数ROI相关性不显著(P > .05)。
- 分割合成图像后所有ROI相关性显著(P < .05),海马r=0.85(P < .001)、丘脑r=0.84(P = .001)、全脑r=0.92(P < .001)。
- z score偏差图与病理异常视觉相关。
诊断标准与关键数值
- 以高场强(1.5-3T)自动分割体积为参考标准,合成图像分割后所有ROI相关性P < .05。
- 海马r=0.85(P < .001)、丘脑r=0.84(P = .001)、全脑r=0.92(P < .001)。
- 直接低场强分割多数ROI相关性P > .05。
局限性
- 单中心前瞻性观察研究的二次分析,外部推广性有限。
- 合成图像基于CNN生成,可能存在与真实高场强图像的残余差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Portable, low-field-strength (0.064-T) MRI has the potential to transform neuroimaging but is limited by low spatial resolution and low signal-to-noise ratio. Purpose To implement a machine learning super-resolution algorithm that synthesizes higher spatial resolution images (1-mm isotropic) from lower resolution T1-weighted and T2-weighted portable brain MRI scans, making them amenable to automated quantitative morphometry. Materials and Methods An external high-field-strength MRI data set (1-mm isotropic scans from the Open Access Series of Imaging Studies data set) and segmentations for 39 regions of interest (ROIs) in the brain were used to train a super-resolution convolutional neural network (CNN). Secondary analysis of an internal test set of 24 paired low- and high-field-strength clinical MRI scans in participants with neurologic symptoms was performed. These were part of a prospective observational study (August 2020 to December 2021) at Massachusetts General Hospital (exclusion criteria: inability to lay flat, body habitus preventing low-field-strength MRI, presence of MRI contraindications). Three well-established automated segmentation tools were applied to three sets of scans: high-field-strength (1.5-3 T, reference standard), low-field-strength (0.064 T), and synthetic high-field-strength images generated from the low-field-strength data with the CNN. Statistical significance of correlations was assessed with Student t tests. Correlation coefficients were compared with Steiger Z tests. Results Eleven participants (mean age, 50 years ± 14; seven men) had full cerebrum coverage in the images without motion artifacts or large stroke lesion with distortion from mass effect. Direct segmentation of low-field-strength MRI yielded nonsignificant correlations with volumetric measurements from high field strength for most ROIs (P > .05). Correlations largely improved when segmenting the synthetic images: P values were less than .05 for all ROIs (eg, for the hippocampus [r = 0.85; P < .001], thalamus [r = 0.84; P = .001], and whole cerebrum [r = 0.92; P < .001]). Deviations from the model (z score maps) visually correlated with pathologic abnormalities. Conclusion This work demonstrated proof-of-principle augmentation of portable MRI with a machine learning super-resolution algorithm, which yielded highly correlated brain morphometric measurements to real higher resolution images. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Ertl-Wagner amd Wagner in this issue. An earlier incorrect version appeared online. This article was corrected on February 1, 2023.
引用
- Iglesias, Schleicher, Laguna, et al. Quantitative Brain Morphometry of Portable Low-Field-Strength MRI Using Super-Resolution Machine Learning. Radiology. 2022. PMID: 36346311. doi:10.1148/radiol.220522
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。