低剂量下肢CTA中迭代重建与深度学习图像重建的动脉狭窄图像质量和诊断准确性比较
研究纳入46例接受低剂量下肢CTA的患者,比较ASIR-V(AV-50、AV-100)与DLIR(DL-M、DL-H)重建的图像质量和动脉狭窄诊断准确性。DLIR图像噪声更低、血管壁更锐利,DL-H整体图像质量评分最高,且与DSA对照的狭窄测量均方误差最低。
要点
- 低剂量下肢CTA中,DLIR较ASIR-V噪声更低、边缘更锐利,DL-H整体图像质量最佳。
- DL-H在诊断动脉狭窄时与DSA对照的均方误差最低,准确性最高。
- AV-100降噪能力最强但图像最模糊,阅片时需注意边缘模糊对狭窄评估的影响。
关键影像表现/征象
- DLIR图像边缘上升斜率更高、边缘上升距离更短,血管壁较ASIR-V更锐利。
- DL-H整体图像质量评分最高,DLIR整体评分优于ASIR-V。
- AV-100图像标准差最低,降噪能力最强,但图像最模糊。
诊断标准与关键数值
- DL-H与DSA对照的狭窄测量均方误差在所有重建组中最低。
- 整体图像质量评分DL-H最高,DLIR组优于ASIR-V组。
临床应用与阅片要点
- 低剂量下肢CTA推荐优先选用DL-H重建,以兼顾图像质量和狭窄诊断准确性。
- AV-100虽降噪最强但边缘最模糊,评估血管狭窄时应避免单独使用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare image quality and diagnostic accuracy of arterial stenosis in low-dose lower-extremity CT angiography (CTA) between adaptive statistical iterative reconstruction-V (ASIR-V) and deep learning image reconstruction (DLIR) algorithms.
METHODS: 46 patients undergoing low-dose lower-extremity CTA were enrolled. Images were reconstructed using ASIR-V (blending factor of 50% (AV-50) and 100% (AV-100)) and DLIR (medium (DL-M), and high (DL-H)). CT values and standard deviation of the aorta, psoas, popliteal artery, popliteal and ankle muscles were measured. The edge-rise distance and edge-rise slope were calculated. The degrees of granularity and edge blurring were assessed using a 5-point scale. The stenosis degrees were measured on the four reconstructions, and their mean square errors against that of digital subtraction angiography were calculated and compared.
RESULTS: For both ASIR-V and DLIR, higher reconstruction intensity generated lower noise and higher signal-to-noise ratio and contrast-to-noise ratio values. The standard deviation values in AV-100 images were significantly lower than other reconstructions. The two DLIR image groups had higher edge-rise slope and lower edge-rise distance (DL-M:1.79 ± 0.37 mm and DL-H:1.82 ± 0.38 mm vs AV-50:1.96 ± 0.39 mm and AV-100:2.01 ± 0.36 mm, p = 0.014) than ASIR-V images. The overall image quality of DLIR was rated higher than ASIR-V (DL-M:0.83 ± 0.61, DL-H:0.41 ± 0.62, AV-50:1.85 ± 0.60 and AV-100:2.37 ± 0.77, p < 0.001), with DL-H having the highest overall image quality score. For stenosis measurement, DL-H had the lowest mean-square-errors compared to digital subtraction angiography among all reconstruction groups.
CONCLUSION: DLIR images had higher image quality ratings with lower image noise and sharper vessel walls in low-dose lower-extremity CTA, and DL-H provides the best overall image quality and highest accuracy in diagnosing artery stenoses.
ADVANCES IN KNOWLEDGE: DLIR provides high-quality images with sharper edges compared to ASIR-V during low-dose CTA of lower extremity arteries, and DLIR (high) provides the best overall image quality and highest accuracy in diagnosing artery stenoses among all reconstruction algorithms (ASIR-V and DLIR). ASIR-V with blending factor of 100% has the strongest noise reduction ability among all reconstruction algorithms (ASIR-V and DLIR); however, it generates the most blurred images.