文献速递心血管MR

心脏MRI与电压标测评估心房纤维化的相关性:系统综述

Correlation between Cardiac MRI and Voltage Mapping in Evaluating Atrial Fibrosis: A Systematic Review.
PubMed 文献 · Radiol Cardiothorac Imaging · 2022-10-13

该系统综述纳入22项研究,评估晚期钆增强心脏MRI与电解剖标测低电压区或组织病理学评估心房纤维化的相关性。

要点

  • LGE心脏MRI高信号区与EAM低电压区或组织病理学所见的纤维化显著相关。
  • 现有研究异质性大,MRI序列与后处理、EAM参数尚未统一,结果解读需谨慎。

核心结论

  • 现有文献提示LGE心脏MRI与LVA EAM或组织病理学在评估心房纤维化时存在相关性。
  • 纳入研究间异质性高,未来需统一心脏MRI与EAM的采集方案。

研究设计与样本

  • 系统综述,检索PubMed、Embase和Cochrane Library截至2022年6月7日的文献,共1048条结果,最终纳入22项研究。
  • 研究方案在PROSPERO注册(CRD42022338243),由两名评价者独立筛选文献。
  • 采用QUADAS-2标准评估纳入研究的偏倚风险与适用性。

关键影像表现/征象

  • LGE心脏MRI上的高信号强度区域与EAM低电压区或组织病理学所见相关。

临床应用与阅片要点

  • 阅片时可关注LGE高信号区,其与EAM低电压区或组织病理学纤维化相关,但需注意研究间异质性大,不能直接套用统一阈值。

局限性

  • 纳入研究在设计、患者样本、心脏MRI采集与后处理、EAM操作方面存在高度异质性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To provide an overview of existing literature on the association between late gadolinium enhancement (LGE) cardiac MRI and low voltage areas (LVA) obtained with electroanatomic mapping (EAM) or histopathology when assessing atrial fibrosis.

MATERIALS AND METHODS: A systematic literature search was conducted in the PubMed, Embase, and Cochrane Library databases to identify all studies published until June 7, 2022, comparing LGE cardiac MRI to LVA EAM and/or histopathology for evaluation of atrial fibrosis. The study protocol was registered at PROSPERO (registration no. CRD42022338243). Two reviewers independently evaluated the studies for inclusion. Risk of bias and applicability for each included study were assessed using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria. Data regarding demographics, electrophysiology, LGE cardiac MRI, and study outcomes were extracted.

RESULTS: The search yielded 1048 total results, of which 22 studies were included. Nineteen of the 22 included studies reported a significant correlation between high signal intensity at LGE cardiac MRI and LVA EAM or histopathology. However, there was great heterogeneity between included studies regarding study design, patient samples, cardiac MRI performance and postprocessing, and EAM performance.

CONCLUSION: Current literature suggests a correlation between LGE cardiac MRI and LVA EAM or histopathology when evaluating atrial fibrosis but high heterogeneity between studies, demonstrating the need for uniform choices regarding cardiac MRI and EAM acquisition in future studies.Keywords: Cardiac, MR Imaging, Left Atrium Supplemental material is available for this article. © RSNA, 2022.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Bijvoet, Nies, Holtackers, et al. Correlation between Cardiac MRI and Voltage Mapping in Evaluating Atrial Fibrosis: A Systematic Review. Radiol Cardiothorac Imaging. 2022. PMID: 36339060. doi:10.1148/ryct.220061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。