文献速递心血管外周血管技术与安全US

剪切波弹性成像颈动脉弹性模量参考值及冠状动脉慢血流动脉僵硬度变化

Reference values of the carotid elastic modulus using shear wave elastography and arterial stiffness change in coronary slow flow.
PubMed 文献 · Eur J Radiol · 2022-10-31

前瞻性队列研究纳入169名健康志愿者和30例冠状动脉慢血流患者,用剪切波弹性成像测量颈动脉弹性模量并建立年龄特异性参考值。年龄和吸烟是弹性模量的主要决定因素,冠状动脉慢血流患者弹性模量高于对照。剪切波弹性成像可无创评估冠状动脉慢血流患者的动脉僵硬度。

要点

  • 年龄是颈动脉最大弹性模量的独立相关因素,弹性模量随年龄增长而升高。
  • 吸烟者在调整年龄后弹性模量仍高于非吸烟者。
  • 冠状动脉慢血流患者颈动脉弹性模量高于年龄和吸烟状态匹配的对照。

核心结论

  • 本研究首次用剪切波弹性成像建立颈动脉弹性模量参考值,年龄和吸烟状态是主要决定因素,冠状动脉慢血流患者弹性模量升高。

研究设计与样本

  • 前瞻性队列研究,纳入169名健康志愿者和30例冠状动脉慢血流患者,用剪切波弹性成像测量颈动脉最大、平均和最小弹性模量。
  • 冠状动脉慢血流以冠状动脉造影时心肌梗死溶栓试验帧计数诊断。

诊断标准与关键数值

  • 建立了按年龄分层的颈动脉弹性模量参考值。
  • 左右颈动脉之间及男女之间弹性模量无差异。
  • 多因素线性回归显示年龄与最大弹性模量独立相关,吸烟对弹性模量有独立影响。

临床应用与阅片要点

  • 阅片时可参考年龄特异性弹性模量参考值判断颈动脉僵硬度是否异常。
  • 报告时需注意吸烟状态对弹性模量的影响,结合年龄和吸烟史解读结果。
  • 对冠状动脉慢血流患者可提示颈动脉弹性模量升高,反映系统性动脉僵硬度增加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Shear wave elastography (SWE) accurately and sensitively evaluates arterial wall stiffness by quantifying the elastic modulus (EM); however, the absence of reference values has precluded its widespread clinical application. This prospective cohort study aimed to establish reference values for the carotid EM using SWE; investigate the main determinants of the EM; and evaluate EM changes in coronary slow flow (CSF), which is characterized by delayed coronary opacification without evident obstructive lesion in epicardial coronary artery on angiography.

METHOD: This study enrolled 169 healthy volunteers and 30 patients with CSF. The carotid maximum EM (EMmax), mean EM, and minimum EM were measured using SWE. CSF was diagnosed by thrombolysis in the myocardial infarction frame count during coronary angiography.

RESULTS: No differences were found in the EM between the left and right carotid arteries and between men and women. Multiple linear regression analysis revealed that age was independently correlated with the EMmax, which progressively increased with age. Moreover, smoking had an independent influence on the EM after adjusting for age; smokers had higher EM than non-smokers. Age-specific reference values for the carotid EM were established. The EM was higher in patients with CSF than in controls after adjusting for age and smoking status.

CONCLUSIONS: This study first established the reference values for the carotid EM using SWE. Age and smoking status were the main determinants of the EM. Patients with CSF had high EM. SWE can effectively and noninvasively evaluate arterial stiffness in patients with CSF.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Kang, Jin, et al. Reference values of the carotid elastic modulus using shear wave elastography and arterial stiffness change in coronary slow flow. Eur J Radiol. 2022. PMID: 36335882. doi:10.1016/j.ejrad.2022.110582

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。