文献速递心血管外周血管技术与安全US

B型超声无创评估动脉脉搏波强度及其在心室功能不全时的降低

Non-invasive Assessment by B-Mode Ultrasound of Arterial Pulse Wave Intensity and Its Reduction During Ventricular Dysfunction.
PubMed 文献 · Ultrasound Med Biol · 2022-11-02

本研究描述一种基于超快扫描平面波B型超声的新方法,通过跟踪连续B型图像中的散斑测量心动周期内血流速度与动脉壁直径变化,评估脉搏波特性。兔主动脉结果与临床动脉内导管系统比较,净前向与后向波模式一致,波速误差量级相似,心室功能不全时波强度降低与波到达延迟可被检测。该方法在健康人颈动脉应用结果与既往测量一致,可能用于心力衰竭筛查。

要点

  • 超快平面波B型超声通过散斑跟踪可无创获取血流速度与动脉壁直径变化。
  • 兔主动脉中,新方法与动脉内导管测得的净前向/后向波模式一致。
  • 心室功能不全时波强度降低和波到达延迟可被新方法检测到。

核心结论

  • 基于超快B型超声散斑跟踪的无创方法可评估动脉脉搏波强度,其波模式与有创导管测量一致,并可在心室功能不全时检测到波强度降低和波到达延迟。

研究设计与样本

  • 方法学研究,在兔主动脉与临床动脉内导管系统比较,并在健康人颈动脉应用,未报告样本量、中心数及具体设备型号。

关键影像表现/征象

  • 通过跟踪连续B型图像中的散斑确定血流速度与动脉壁直径,利用奇异值分解分离血液散斑与组织并校正超声成像测速偏差。
  • 兔主动脉中,新方法与基于血流速度和压力的常规分析相比,净前向波与后向波模式一致。
  • 心室功能不全时,两种方法均检测到波强度降低和波到达延迟。

诊断标准与关键数值

  • 原文未报告敏感度、特异度、AUC、阈值或分级标准。

临床应用与阅片要点

  • 该方法可能用于无创评估动脉脉搏波特性,并有望用于心力衰竭筛查,但需进一步临床验证。

局限性

  • 临床动脉内导管系统频率响应较差且滞后更大。
  • 研究仅在兔主动脉和一名健康人颈动脉中应用,样本量小,临床验证有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Arterial pulse waves contain clinically useful information about cardiac performance, arterial stiffness and vessel tone. Here we describe a novel method for non-invasively assessing wave properties, based on measuring changes in blood flow velocity and arterial wall diameter during the cardiac cycle. Velocity and diameter were determined by tracking speckles in successive B-mode images acquired with an ultrafast scanner and plane-wave transmission. Blood speckle was separated from tissue by singular value decomposition and processed to correct biases in ultrasound imaging velocimetry. Results obtained in the rabbit aorta were compared with a conventional analysis based on blood velocity and pressure, employing measurements obtained with a clinical intra-arterial catheter system. This system had a poorer frequency response and greater lags but the pattern of net forward-traveling and backward-traveling waves was consistent between the two methods. Errors in wave speed were also similar in magnitude, and comparable reductions in wave intensity and delays in wave arrival were detected during ventricular dysfunction. The non-invasive method was applied to the carotid artery of a healthy human participant and gave a wave speed and patterns of wave intensity consistent with earlier measurements. The new system may have clinical utility in screening for heart failure.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Rowland, Riemer, Lichtenstein, et al. Non-invasive Assessment by B-Mode Ultrasound of Arterial Pulse Wave Intensity and Its Reduction During Ventricular Dysfunction. Ultrasound Med Biol. 2022. PMID: 36335055. doi:10.1016/j.ultrasmedbio.2022.09.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。