床旁超声骨折-骺板距离与儿童桡骨远端Salter-Harris II型骨折的关联:「POCUS 1-cm法则」
本研究为澳大利亚三级儿童急诊前瞻性诊断研究的二次分析,由两名急诊超声医师测量122例X线确诊桡骨远端骨折患儿的床旁超声骨折-骺板距离。Salter-Harris II型骨折(n=19)中位数8.00 mm、最大9.85 mm,不完全骨折(n=22)最小10.20 mm、中位数15.98 mm。1 cm截断值可区分Salter-Harris II型与其他皮质断裂型骨折,但不能区分青枝骨折。
要点
- POCUS测得骨折-骺板距离≤1 cm提示Salter-Harris II型可能,可作为辅助征象。
- 该1 cm截断值不能区分Salter-Harris II与青枝(buckle)骨折。
- 测量需在2小时培训后按六视图POCUS方案进行,结果为探索性、需前瞻验证。
核心结论
- 在X线确诊桡骨远端骨折的儿童中,POCUS骨折-骺板距离1 cm截断值可区分Salter-Harris II型与其他皮质断裂型骨折,但不能区分青枝骨折。
- 作者认为「POCUS 1-cm法则」可作为辅助征象增强POCUS对Salter-Harris II型桡骨远端骨折的诊断,但需前瞻性验证。
研究设计与样本
- 研究类型为母诊断研究的二次分析,母研究在澳大利亚三级儿童急诊前瞻性评估POCUS对比X线诊断儿童远端前臂骨折。
- 样本为母研究中122例X线确诊桡骨远端骨折的参与者,由两名急诊超声医师独立解读POCUS图像并测量骨折-骺板距离。
- POCUS由接受2小时培训的执业护士在X线检查前对临床无成角的儿童前臂损伤执行六视图方案。
- 参考标准为X线诊断的桡骨远端骨折。
诊断标准与关键数值
- Salter-Harris II型骨折(n=19)骨折-骺板距离中位数8.00 mm、最大9.85 mm。
- 不完全骨折(n=22)最小距离10.20 mm、中位数15.98 mm;完全骨折(n=9)最小10.85 mm、中位数12.85 mm。
- 青枝骨折(n=72)距离范围4.35–26.55 mm,中位数13.65 mm。
- 1 cm骨折-骺板距离截断值可区分Salter-Harris II型与其他皮质断裂型骨折,但不能区分青枝骨折。
临床应用与阅片要点
- 对临床无成角的儿童前臂损伤,可在X线前按六视图POCUS方案测量骨折-骺板距离,≤1 cm时提示Salter-Harris II型可能。
- 报告时应注明该征象为辅助性,不能替代X线,且青枝骨折亦可出现≤1 cm距离。
局限性
- 原文为探索性研究,作者明确指出需前瞻性研究验证该测量。
- 本研究为母诊断研究的二次分析,样本来自单一澳大利亚三级儿童急诊中心。
- POCUS由接受2小时培训的执业护士执行,测量由两名急诊超声医师完成,结果可重复性未在原文报告。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Salter-Harris II fractures of the distal radius can result in serious complications. The aim of this study was to measure the fracture-physis distance using point-of-care ultrasound (POCUS) to determine whether a certain distance is associated with Salter-Harris II fractures, compared with other fracture types, in a cohort of children with X-ray-identified distal radius fractures. Participants were from a parent diagnostic study conducted in an Australian tertiary pediatric emergency department, which prospectively evaluated the diagnosis of pediatric distal forearm fractures using POCUS compared against X-ray. Nurse practitioners, who underwent 2 h of training, administered a six-view POCUS protocol in clinically non-angulated pediatric forearm injuries prior to X-ray. This was a secondary analysis of data from the parent study. The 122 participants with X-ray-identified distal radius fractures from the parent study had their POCUS images interpreted by two emergency physician sonologists, who measured the fracture-physis distance. The median and maximum fracture-physis distances for Salter-Harris II fractures (n = 19) were 8.00 and 9.85 mm, whereas minimum and median distances for incomplete fractures (n = 22) were 10.20 and 15.98 mm, and those for complete fractures (n = 9) were 10.85 and 12.85 mm. Buckle fracture (n = 72) distances ranged from 4.35 to 26.55 mm, with a median of 13.65 mm. In children diagnosed with a distal radius fracture on X-ray, a fracture-physis distance cutoff of 1 cm differentiated Salter-Harris II fractures from other cortical breach fracture types, but not buckle fractures. Although this exploratory study suggests the "POCUS 1-cm rule" could be used as a secondary sign to augment the diagnosis of Salter-Harris II distal radius fractures using POCUS, further research is required to validate this measurement prospectively.
引用
- Snelling, Jones, Gillespie, et al. Point-of-Care Ultrasound Fracture-Physis Distance Association with Salter-Harris II Fractures of the Distal Radius in Children: The "POCUS 1-cm Rule". Ultrasound Med Biol. 2022. PMID: 36333153. doi:10.1016/j.ultrasmedbio.2022.10.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。