腹部内脏脂肪CT自动分割方法的开发与验证
本研究开发了一种三步法全腹部内脏脂肪CT自动分割方法,在99例接受PET/CT筛查者的CT图像上与手动分割比较,自动分割VAT体积与手动分割高度相关(r=0.9676,p<0.0001),提示该方法可行并可用于临床测量VAT体积和HU。
要点
- 三步法自动分割全腹部内脏脂肪与手动分割VAT体积高度相关(r=0.9676)。
- 相似性指数与VAT体积正相关,与平均HU负相关。
- Bland-Altman分析显示少数测量值在1.96SD之外,方法可用于日常临床。
核心结论
- 开发的全腹部内脏脂肪自动分割方法可行,能用于测量VAT体积和VAT的HU值。
研究设计与样本
- 方法学研究,采用三步流程依次分割肺、软组织和椎后间隙三个解剖区域以实现VAT自动分割。
- 采用相似性指数和Pearson相关分析比较自动与手动分割,并测量体重、身高、葡萄糖和胰岛素等临床数据。
诊断标准与关键数值
- 自动分割VAT体积(3,594.6 ± 1,776.5 cm³)与手动分割(3,375.7 ± 1,567.5 cm³)强相关(r=0.9676,p<0.0001)。
- 相似性指数与VAT体积正相关(r=0.6396,p<0.0001),与平均HU负相关(r=-0.4328,p<0.0001)。
- Bland-Altman分析示VAT体积有5.1%、平均HU有7.1%的点在均值1.96个标准差之外。
临床应用与阅片要点
- 自动分割可替代耗时的手动全腹部VAT分割,便于在日常临床中提供VAT体积和HU的详细信息。
- 相似性指数随VAT体积增大而升高、随平均HU降低而升高,解读自动分割结果时需考虑VAT体积和密度对分割一致性的影响。
局限性
- 验证样本仅99例,且来自单一PET/CT癌症筛查人群,外推至其他人群或CT设备需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Imaging modalities such as computed tomography (CT) or magnetic resonance imaging have been used to measure adiposity. However, manual segmentation of visceral adipose tissue (VAT) in the entire abdomen is laborious and time-consuming. We aimed to develop a new method for accurate visceral fat segmentation by automatically dividing the three anatomical compartments of the lung, soft tissue, and post-vertebral spaces.
METHODS: To automatically separate visceral fat, a three-step process was performed that sequentially divided tissues and regions in a three-dimensional CT image. Manual segmentation was performed in 99 individuals who underwent 18-fluoro-2-deoxyglucosepositron emission tomography/CT for cancer screening between January 2010 and December 2018 to validate the automated segmentation. The similarity index and Pearson's correlation analysis were performed to compare automated segmentation with manual segmentation. Clinical data, such as weight, height, and glucose and insulin levels, were measured. Pearson's correlation analysis was performed to investigate the association between the two methods.
RESULTS: VAT volume of automated segmentation (3,594.6 ± 1,776.5 cm3) strongly correlated with that of manual segmentation (3,375.7 ± 1567.5 cm3) (r = 0.9676, p < 0.0001). The similarity index positively correlated with the VAT volume (r = 0.6396, p < 0.0001) and negatively correlated with the mean Hounsfield units (HU) (r = -0.4328, p < 0.0001). Bland-Altman plots are presented with 5.1 % for VAT volume and 7.1 % for mean HU were outside 1.96 standard deviation from the mean value.
CONCLUSION: We developed an automated segmentation method for VAT in the entire abdomen. This automated segmentation method is feasible for measuring the VAT volume and VAT HU. This method could be employed in daily clinical practice to provide more detailed information about VAT.
引用
- Hwang, Pak. Development of automated segmentation of visceral adipose tissue in computed tomography. Eur J Radiol. 2022. PMID: 36327856. doi:10.1016/j.ejrad.2022.110559
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。