超声造影与高分辨率磁共振诊断颈动脉易损斑块的系统评价与荟萃分析
该系统评价纳入9篇文献,比较超声造影(CEUS)与高分辨率磁共振(HR-MRI)诊断颈动脉易损斑块的效能。CEUS汇总敏感度91%、特异度67%,HR-MRI分别为78%和65%,两者曲线下面积分别为0.9218和0.8129,诊断准确性差异无统计学意义。CEUS敏感度高于HR-MRI,特异度相近,可作为诊断颈动脉易损斑块的有用工具。
要点
- CEUS诊断颈动脉易损斑块的汇总敏感度91%、特异度67%,敏感度高于HR-MRI。
- HR-MRI汇总敏感度78%、特异度65%,与CEUS诊断准确性差异无统计学意义。
- CEUS曲线下面积0.9218,HR-MRI为0.8129,两者诊断效能相近。
核心结论
- CEUS检测颈动脉易损斑块的敏感度高于HR-MRI,特异度与HR-MRI相似。
- CEUS与HR-MRI在检测易损斑块方面的诊断效能相似,差异无统计学意义。
- CEUS可能是诊断颈动脉易损斑块的有用工具。
研究设计与样本
- 系统评价与荟萃分析,检索PubMed、Embase、Cochrane Library和Web of Science自建库至2021年12月。
- 共纳入9篇文章,使用Meta-DiSc 1.4进行统计分析。
- 探讨了CEUS和HR-MRI异质性的潜在来源。
诊断标准与关键数值
- CEUS检测颈动脉易损斑块的汇总敏感度91%(95%CI:84%,95%),特异度67%(95%CI:54%,79%)。
- HR-MRI检测颈动脉易损斑块的汇总敏感度78%(95%CI:72%,83%),特异度65%(95%CI:56%,73%)。
- CEUS和HR-MRI的汇总受试者工作特征曲线下面积分别为0.9218和0.8129。
临床应用与阅片要点
- CEUS可作为诊断颈动脉易损斑块的影像学工具,其敏感度高于HR-MRI。
- CEUS与HR-MRI诊断准确性相近,临床选择可结合设备条件和患者情况。
局限性
- 纳入研究数量较少(9篇),可能影响结果的稳健性。
- CEUS和HR-MRI均存在异质性,研究间诊断标准可能不一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this meta-analysis was to evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) and high-resolution magnetic resonance imaging (HR-MRI) in patients with carotid vulnerable plaques.
METHODS: A systematic review was conducted in PubMed, Embase, Cochrane Library, and Web of Science using the search terms carotid artery, atherosclerotic plaque, CEUS, contrast-enhanced ultrasound, HR-MRI, and high-resolution magnetic resonance. Studies published since the establishment of the library until December 2021 were retrieved. The statistical analyses were performed with Meta-DiSc version 1.4. Beyond that, the potential sources of heterogeneity for CEUS and HR-MRI were explored.
RESULTS: Nine articles were included in this study. For CEUS, the pooled sensitivity and specificity for detecting carotid vulnerable plaques 91% (95% confidence interval [CI]: 84%, 95%) and 67% (95% CI: 54%, 79%), respectively. For HR-MRI, the pooled sensitivity and specificity were 78% (95% CI: 72%, 83%) and 65% (95% CI, 56%, 73%), respectively. The area under the summary receiver operating characteristic curve for CEUS and HR-MRI were 0.9218 and 0.8129, respectively. However, the difference in diagnostic accuracy between CEUS and HR-MRI diagnostic accuracy was not statistically significant.
CONCLUSIONS: The study shows that the sensitivity of CEUS was higher than that of HR-MRI, and the specificity was similar to HR-MRI. CEUS and HR-MRI provide a similar diagnostic yield in detecting a vulnerable plaque. Thus, CEUS may be a useful tool for the diagnosis of carotid vulnerable plaques.
引用
- Li, Cai, Wang, et al. Diagnostic Performance of Contrast-Enhanced Ultrasound and High-Resolution Magnetic Resonance Imaging for Carotid Atherosclerotic Plaques: A Systematic Review and Meta-Analysis. J Ultrasound Med. 2022. PMID: 36321389. doi:10.1002/jum.16122
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。