文献速递神经骨肌MR

深度学习重建用于加速脊柱MRI:前瞻性可互换性分析

Deep Learning Reconstruction for Accelerated Spine MRI: Prospective Analysis of Interchangeability.
PubMed 文献 · Radiology · 2022-11-01

这项前瞻性单中心研究纳入50例脊柱异常受试者,比较标准全采样TSE与DL重建欠采样TSE(TSEDL)的T1/T2加权图像。结果显示TSEDL总采集时间最多缩短70%(100秒 vs 328秒,P<.001),个体等效指数均<4%,在主要发现频率、整体图像质量及诊断信心上与标准TSE无差异,噪声评分更优。

要点

  • TSEDL可将脊柱T1/T2加权TSE总采集时间从328秒缩短至100秒,降幅达70%。
  • TSEDL与标准TSE在主要发现频率、整体图像质量和诊断信心上无显著差异,可互换。
  • 所有读者均认为TSEDL图像噪声更优(P<.001),支持其用于临床脊柱MRI加速。

核心结论

  • DL重建的TSE方法在检测脊柱各种异常方面与标准TSE具有可互换性,图像质量优秀且检查时间缩短70%。

研究设计与样本

  • 前瞻性单中心研究,纳入50例有各种脊柱异常的受试者(平均年龄46岁±18,26名男性),每人均接受标准全采样TSE(参考标准)和前瞻性欠采样TSEDL(三倍和四倍加速)两次MRI检查。
  • 图像由5名读者评估,采用可互换性分析和基于图像质量的分析比较TSE与TSEDL,并比较采集时间和诊断信心。

关键影像表现/征象

  • TSEDL总采集时间最多缩短70%(TSEDL 100秒 vs TSE 328秒,P<.001)。
  • 所有读者均评价TSEDL图像噪声更优(P<.001)。
  • 标准TSE与TSEDL在主要发现频率、整体图像质量或诊断信心方面无差异证据。

诊断标准与关键数值

  • 可互换性采用个体等效指数评估各种退变和非退变实体,按椎体分析,不一致临床判断定义为低于5%。
  • 所有个体等效指数均小于4%。

临床应用与阅片要点

  • TSEDL可用于加速脊柱MRI T1和T2加权TSE采集,在保持诊断信心和主要发现检出率的同时显著缩短检查时间。
  • 阅片时需注意TSEDL图像噪声更优,但整体图像质量与标准TSE无差异,可放心用于常规报告。

局限性

  • 单中心前瞻性研究,样本量50例,需多中心更大样本验证。
  • 仅评估了脊柱T1和T2加权TSE序列,未涉及其他序列或部位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning (DL)-based MRI reconstructions can reduce examination times for turbo spin-echo (TSE) acquisitions. Studies that prospectively employ DL-based reconstructions of rapidly acquired, undersampled spine MRI are needed. Purpose To investigate the diagnostic interchangeability of an unrolled DL-reconstructed TSE (hereafter, TSEDL) T1- and T2-weighted acquisition method with standard TSE and to test their impact on acquisition time, image quality, and diagnostic confidence. Materials and Methods This prospective single-center study included participants with various spinal abnormalities who gave written consent from November 2020 to July 2021. Each participant underwent two MRI examinations: standard fully sampled T1- and T2-weighted TSE acquisitions (reference standard) and prospectively undersampled TSEDL acquisitions with threefold and fourfold acceleration. Image evaluation was performed by five readers. Interchangeability analysis and an image quality-based analysis were used to compare the TSE and TSEDL images. Acquisition time and diagnostic confidence were also compared. Interchangeability was tested using the individual equivalence index regarding various degenerative and nondegenerative entities, which were analyzed on each vertebra and defined as discordant clinical judgments of less than 5%. Interreader and intrareader agreement and concordance (κ and Kendall τ and W statistics) were computed and Wilcoxon and McNemar tests were used. Results Overall, 50 participants were evaluated (mean age, 46 years ± 18 [SD]; 26 men). The TSEDL method enabled up to a 70% reduction in total acquisition time (100 seconds for TSEDL vs 328 seconds for TSE, P < .001). All individual equivalence indexes were less than 4%. TSEDL acquisition was rated as having superior image noise by all readers (P < .001). No evidence of a difference was found between standard TSE and TSEDL regarding frequency of major findings, overall image quality, or diagnostic confidence. Conclusion The deep learning (DL)-reconstructed turbo spin-echo (TSE) method was found to be interchangeable with standard TSE for detecting various abnormalities of the spine at MRI. DL-reconstructed TSE acquisition provided excellent image quality, with a 70% reduction in examination time. German Clinical Trials Register no. DRKS00023278 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Hallinan in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Almansour, Herrmann, Gassenmaier, et al. Deep Learning Reconstruction for Accelerated Spine MRI: Prospective Analysis of Interchangeability. Radiology. 2022. PMID: 36318032. doi:10.1148/radiol.212922

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。