文献速递腹部技术与安全MRPET

FDG-PET/MRI在腹膜癌术前诊断与分期中的多阅片者前瞻性预试验

FDG-PET/MRI for the preoperative diagnosis and staging of peritoneal carcinomatosis: a prospective multireader pilot study.
PubMed 文献 · Abdom Radiol (NY) · 2022-10-29

这项单中心前瞻性预试验纳入14例腹膜癌患者,术前用FDG-PET/MRI以Sugarbaker腹膜癌指数(PCI)为参考标准评估诊断效能。FDG-PET/MRI在患者水平合并敏感度、特异度和准确率分别为91.7%、50%和85.7%,区域水平敏感度仅52.7%;阅片者间一致性近乎完美(Kappa 0.81-0.98)。

要点

  • FDG-PET/MRI患者水平诊断准确率85.7%,高于单独MRI(71.4%)和FDG-PET(64.3%)。
  • 区域水平敏感度FDG-PET/MRI仅52.7%,但显著高于单独MRI(37%)和FDG-PET(17.8%)。
  • 以PCI 20为界值时,FDG-PET/MRI达到100%敏感度和100%特异度。

核心结论

  • FDG-PET/MRI对腹膜癌的患者水平诊断准确率优秀,但区域水平检测效能较弱。
  • FDG-PET/MRI相对于单独MRI或FDG-PET的附加价值尚待确定。

研究设计与样本

  • 单中心前瞻性预试验,纳入14例成人腹膜癌患者(男/女:3/11,平均年龄57±12岁)。
  • 患者术前接受FDG-PET/MRI(平均间隔14天,范围1-63天),以手术Sugarbaker腹膜癌指数(PCI)为参考标准。
  • 由2名腹部放射科医师独立评估增强腹部MR图像,2名核医学医师独立评估融合T2加权图像的PET图像。
  • 腹部划分为13个区域,每个区域评分0-3分,结合研究数据生成混合FDG-PET/MRI放射学PCI。
  • 在患者水平和区域水平比较放射学PCI与手术PCI,并评估阅片者间一致性。

诊断标准与关键数值

  • 患者水平合并敏感度/特异度/准确率:MRI为75%/50%/71.4%,FDG-PET为66.7%/50%/64.3%,FDG-PET/MRI为91.7%/50%/85.7%(组间无显著差异,P值范围0.13-1)。
  • 以PCI 20为界值时,FDG-PET/MRI的敏感度和特异度均为100%。
  • 区域水平敏感度/准确率:MRI为37%/61.8%,FDG-PET为17.8%/64.3%,FDG-PET/MRI为52.7%/60.4%,FDG-PET/MRI敏感度显著更高。
  • 区域水平特异度:FDG-PET为95%,MRI为78.4%,FDG-PET/MRI为66.5%。
  • 所有阅片组放射学PCI的阅片者间一致性近乎完美(Kappa:0.81-0.98)。

临床应用与阅片要点

  • FDG-PET/MRI适合患者水平术前分期,但区域水平检测敏感度有限,报告时需注意可能低估区域病变范围。
  • 以PCI 20为界值时诊断效能极佳,但该阈值来自小样本预试验,需谨慎外推。
  • 阅片者间一致性高(Kappa 0.81-0.98),提示标准化评分流程可重复性好。

局限性

  • 单中心前瞻性预试验,样本量仅14例,结论需更大样本验证。
  • FDG-PET/MRI相对于MRI或FDG-PET的附加价值尚未确定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic performance of FDG-PET/MRI for the preoperative diagnosis and staging of peritoneal carcinomatosis (PC) using surgical Sugarbaker's PC index (PCI) as the reference in a multireader pilot study.

METHODS: Fourteen adult patients (M/F: 3/11, mean age: 57 ± 12 year) with PC were prospectively included in this single-center study. Patients underwent FDG-PET/MRI prior to surgery (mean delay: 14 d, range: 1-63 d). Images were reviewed independently by 2 abdominal radiologists and 2 nuclear medicine physicians. The radiologists assessed contrast-enhanced abdominal MR images, while the nuclear medicine physicians assessed PET images fused with T2-weighted images. The abdomen was divided in 13 regions, scored from 0 to 3. A hybrid FDG-PET/MRI radiological PCI was created by combining the study data. Radiological PCI was compared to the surgical PCI on a per-patient and per-region basis. Inter-reader agreement was evaluated.

RESULTS: Mean surgical PCI was 10 ± 8 (range: 0-24). Inter-reader agreement was almost perfect for all sets for radiologic PCI (Kappa: 0.81-0.98). PCI scores for all reading sets significantly correlated with the surgical PCI score (r range: 0.57-0.74, p range: < 0.001-0.003). Pooled per-patient sensitivity, specificity, and accuracy were 75%/50%/71.4% for MRI, 66.7%/50%/64.3% for FDG-PET, and 91.7%/50%/85.7% for FDG-PET/MRI, without significant difference (p value range 0.13-1). FDG-PET/MRI achieved 100% sensitivity and 100% specificity for a cutoff PCI of 20. Per-region sensitivity and accuracy were lower: 37%/61.8% for MRI, 17.8%/64.3% for FDG-PET, and 52.7%/60.4% for FDG-PET/MRI, with significantly higher sensitivity for FDG-PET/MRI. Per-region specificity was higher for FDG-PET (95%) compared to MRI (78.4%) and FDG-PET/MRI (66.5%).

CONCLUSION: FDG-PET/MRI achieved an excellent diagnostic accuracy per-patient and weaker performance per-region for detection of PC. The added value of PET/MRI compared to MRI and FDG-PET remains to be determined.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Vietti Violi, Gavane, Argiriadi, et al. FDG-PET/MRI for the preoperative diagnosis and staging of peritoneal carcinomatosis: a prospective multireader pilot study. Abdom Radiol (NY). 2022. PMID: 36308554. doi:10.1007/s00261-022-03703-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。