文献速递胸部CT

常规胸部CT上间质性肺异常(ILA):放射科医生视觉评估与自动定量检测的对比

Interstitial lung abnormalities (ILA) on routine chest CT: Comparison of radiologists' visual evaluation and automated quantification.
PubMed 文献 · Eur J Radiol · 2022-10-17

本研究为单中心回顾性研究,共纳入336例受试者(含ILA病例及1:2匹配对照),以两名胸部放射科医生依据Fleischner学会指南的共识作为参考标准,评估一种全自动定量软件检测常规胸部CT上ILA的性能。结果显示医生间对ILA存在与否的一致性为较高度(加权κ=0.74),对亚型仅为一般(加权κ=0.38);系统以至少一个肺区5%为阈值时敏感度67.6%、特异度93.3%、准确度90.5%,最佳界值为3.6%(敏感度84.8%、特异度92.4%)。结论认为自动定量系统有助于客观识别ILA。

要点

  • 系统以至少一个肺区5%为阈值检测ILA:敏感度67.6%、特异度93.3%、准确度90.5%。
  • 系统检测ILA的最佳界值为3.6%,敏感度84.8%、特异度92.4%。
  • 医生间对ILA存在的一致性较高度(κ=0.74),对亚型仅一般(κ=0.38)。

核心结论

  • 全自动定量系统用于常规胸部CT检测ILA具有较高特异度和准确度,有助于客观识别ILA。
  • 医生间对ILA存在与否的一致性为较高度,但对ILA亚型的一致性仅为一般。

研究设计与样本

  • 单中心回顾性研究,共纳入336例受试者(平均年龄70.5±6.1岁;男女比282:54),包括ILA病例及1:2匹配对照。
  • 受试者因健康筛查接受采用多种CT协议的常规胸部CT检查。
  • 由两名胸部放射科医生依据Fleischner学会指南独立阅片,以其共识作为ILA的参考标准。
  • 通过改良基于深度学习的间质性肺疾病定量方法,开发了全自动定量工具用于检测ILA。

诊断标准与关键数值

  • 系统以至少一个肺区5%为阈值识别ILA:敏感度67.6%、特异度93.3%、准确度90.5%。
  • 系统检测ILA的最佳异常范围界值为3.6%:敏感度84.8%、特异度92.4%。
  • 医生间对ILA存在与否的加权κ为0.74,对ILA亚型的加权κ为0.38。

临床应用与阅片要点

  • 自动定量系统可作为辅助工具,帮助客观识别常规胸部CT上的ILA。
  • 系统判定为阳性而读者判为阴性时,需注意读者可能低估了ILA范围:20例假阳性中8例(40%)为读者低估ILA范围所致。
  • 特定厂商的对比增强扫描和吸气不佳可导致系统出现真性假阳性(均P<0.05),阅片时需结合扫描条件判断。

局限性

  • 本研究为单中心回顾性设计,结论外推需谨慎。
  • 医生间对ILA亚型的一致性仅为一般(加权κ=0.38),亚型参考标准本身存在不确定性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to evaluate the performance of a fully automated quantitative software in detecting interstitial lung abnormalities (ILA) according to the Fleischner Society guidelines on routine chest CT compared with radiologists' visual analysis.

METHOD: This retrospective single-centre study included participants with ILA findings and 1:2 matched controls who underwent routine chest CT using various CT protocols for health screening. Two thoracic radiologists independently reviewed the CT images using the Fleischner Society guidelines. We developed a fully automated quantitative tool for detecting ILA by modifying deep learning-based quantification of interstitial lung disease and evaluated its performance using the radiologists' consensus for ILA as a reference standard.

RESULTS: A total of 336 participants (mean age, 70.5 ± 6.1 years; M:F = 282:54) were included. Inter-reader agreements were substantial for the presence of ILA (weighted κ, 0.74) and fair for its subtypes (weighted κ, 0.38). The quantification system for identifying ILA using a threshold of 5 % in at least one zone showed 67.6 % sensitivity, 93.3 % specificity, and 90.5 % accuracy. Eight of 20 (40 %) false positives identified by the system were underestimated by readers for ILA extent. Contrast-enhancement in a certain vendor and suboptimal inspiration caused a true false-positive on the system (all P < 0.05). The best cut-off value of abnormality extent detecting ILA on the system was 3.6 % (sensitivity, 84.8 %; specificity 92.4 %).

CONCLUSIONS: Inter-reader agreement was substantial for ILA but only fair for its subtypes. Applying an automated quantification system in routine clinical practice may aid the objective identification of ILA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim, Choe, Hwang, et al. Interstitial lung abnormalities (ILA) on routine chest CT: Comparison of radiologists' visual evaluation and automated quantification. Eur J Radiol. 2022. PMID: 36308851. doi:10.1016/j.ejrad.2022.110564

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。