3D高分辨率MRI评估颅内动脉粥样硬化狭窄程度:与TOF-MRA、CE-MRA及DSA的比较
本研究以颅内动脉缺血事件患者为对象,比较3D高分辨率MRI(HR-MRI)、TOF-MRA、CE-MRA与DSA测量颅内动脉粥样硬化狭窄程度的相关性和一致性。93例患者共189处动脉狭窄,其中72例142处狭窄行DSA检查。HR-MRI与DSA测量呈极强相关(r=0.864,p<0.0001),一致性K=0.772,优于TOF-MRA(K=0.636),与CE-MRA(K=0.734)相近;HR-MRI能通过直接显示血管腔和狭窄闭塞斑块准确测量狭窄,尤其对中重度狭窄。
要点
- HR-MRI与DSA测量狭窄程度呈极强相关(r=0.864),一致性K=0.772,优于TOF-MRA。
- HR-MRI可直接显示血管腔及狭窄闭塞斑块,对中重度狭窄测量准确。
- TOF-MRA与DSA相关性较强(r=0.686)但一致性仅中等(K=0.636),评估狭窄需谨慎。
核心结论
- HR-MRI通过直接可视化血管腔和狭窄闭塞斑块,能准确测量颅内动脉粥样硬化狭窄,尤其对中重度狭窄。
- HR-MRI与DSA测量相关性(r=0.864)和一致性(K=0.772)均优于TOF-MRA(r=0.686,K=0.636),与CE-MRA(r=0.843,K=0.734)相近。
研究设计与样本
- 回顾性比较研究,纳入因颅内动脉缺血事件行HR-MRI、TOF-MRA及CE-MRA分析的患者,部分行DSA检查。
- 共93例患者189处动脉狭窄;其中72例142处狭窄行DSA检查作为参考标准。
- 比较HR-MRI、TOF-MRA、CE-MRA与DSA测量狭窄程度的相关性和一致性。
关键影像表现/征象
- HR-MRI可直接显示血管腔和导致狭窄闭塞的斑块,用于测量狭窄程度。
- HR-MRI与CE-MRA测量呈极强相关(r=0.839,p<0.0001),与TOF-MRA呈强相关(r=0.720,p<0.0001)。
诊断标准与关键数值
- HR-MRI与DSA测量狭窄程度极强相关(r=0.864,p<0.0001),一致性K=0.772。
- CE-MRA与DSA测量极强相关(r=0.843,p<0.0001),一致性K=0.734。
- TOF-MRA与DSA测量强相关(r=0.686,p<0.0001),一致性K=0.636。
临床应用与阅片要点
- HR-MRI可用于颅内动脉粥样硬化狭窄程度的准确评估,尤其适用于中重度狭窄的测量。
- TOF-MRA与DSA一致性中等(K=0.636),基于TOF-MRA判断狭窄程度时需注意其可能高估或低估。
- CE-MRA与HR-MRI测量相关性极强(r=0.839),两者可互为补充。
局限性
- 原文未明确报告研究局限性。
- 部分患者未行DSA检查,仅72例142处狭窄有DSA参考标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the accuracy of three-dimensional (3D) high-resolution (HR) magnetic resonance imaging (MRI), time-of-flight magnetic resonance angiography (TOF-MRA), contrast-enhanced magnetic resonance angiography (CE-MRA), and digital subtraction angiography (DSA) in measuring the degree of stenosis in intracranial atherosclerosis.
MATERIALS AND METHODS: All patients with intracranial artery ischaemic events underwent HR-MRI, TOF-MRA, and CE-MRA analysis, and some of these patients underwent DSA examination. The correlation between different methods for measuring the degree of lumen stenosis was analysed. The accuracy of HR-MRI, TOF-MRA, and CE-MRA was evaluated and compared with that of DSA.
RESULTS: A total of 189 arterial stenoses were identified in 93 patients. Of these, 72 patients with 142 arterial stenoses underwent DSA examination. A very strong correlation between HR-MRI and CE-MRA measurements was shown (r=0.839, p<0.0001). The correlation between HR-MRI and TOF-MRA measurements was strong (r=0.720, p<0.0001). A very strong correlation between HR-MRI and DSA measurements was found (r=0.864, p<0.0001), and a similar correlation was observed between CE-MRA, and DSA measurements (r=0.843, p<0.0001). The correlation between TOF-MRA and DSA measurements was strong (r=0.686, p<0.0001). There was substantial agreement between HR-MRI and DSA measurements (K = 0.772) and between CE-MRA, and DSA measurements (K = 0.734) that was slightly higher than the agreement between TOF-MRA and DSA measurements (K = 0.636).
CONCLUSION: HR-MRI can accurately measure stenosis (especially for moderate and severe stenosis) in intracranial atherosclerosis by direct visualisation of the vessel lumen and steno-occlusive plaque.
引用
- Zhao, Li, Li, et al. Assessment of the degree of arterial stenosis in intracranial atherosclerosis using 3D high-resolution MRI: comparison with time-of-flight MRA, contrast-enhanced MRA, and DSA. Clin Radiol. 2022. PMID: 36307233. doi:10.1016/j.crad.2022.08.132
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。