文献速递骨肌外周血管儿科影像MR

基于影像组学的机器学习方法鉴别纤维脂肪血管异常与静脉畸形

Radiomics-based machine learning approach in differentiating fibro-adipose vascular anomaly from venous malformation.
PubMed 文献 · Pediatr Radiol · 2022-10-22

本研究回顾性分析178例儿童、青少年及年轻成人血管畸形患者的MRI,构建基于T1WI和脂肪抑制T2WI的影像组学机器学习模型,用于鉴别纤维脂肪血管异常与常见静脉畸形。基于LASSO或Boruta特征选择的多序列逻辑回归模型在交叉验证中AUC达97%,敏感度94%–95%,特异度87%–89%,显示良好鉴别潜力。

要点

  • 纤维脂肪血管异常与静脉畸形影像重叠,易误诊,需注意鉴别。
  • 基于轴位FS T2WI、冠状位FS T2WI和轴位T1WI的多序列影像组学模型鉴别性能最佳。
  • LASSO与Boruta特征选择策略构建的模型性能相近。

局限性

  • 回顾性研究设计。
  • 单中心样本。
  • 模型性能基于交叉验证,尚未外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: As a complex vascular malformation, fibro-adipose vascular anomaly was first proposed in 2014. Its overlap with other vascular malformations regarding imaging and clinical features often leads to misdiagnosis and improper management.

OBJECTIVE: To construct a radiomics-based machine learning model to help radiologists differentiate fibro-adipose vascular anomaly from common venous malformations.

MATERIALS AND METHODS: We retrospectively analyzed 178 children, adolescents and young adults with vascular malformations (41 fibro-adipose vascular anomaly and 137 common vascular malformation cases) who underwent MRI before surgery between May 2012 to January 2021. We extracted radiomics features from T1-weighted images and fat-saturated (FS) T2-weighted images and further selected features through least absolute shrinkage and selection operator (LASSO) and Boruta methods. We established eight weighted logistic regression classification models based on various combinations of feature-selection strategies (LASSO or Boruta) and sequence types (single- or multi-sequence). Finally, we evaluated the performance of each model by the mean area under the receiver operating characteristics curve (ROC-AUC), sensitivity and specificity in 10 runs of repeated k-fold (k = 10) cross-validation.

RESULTS: Two multi-sequence models based on axial FS T2-W, coronal FS T2-W and axial T1-W images showed promising performance. The LASSO-based multi-sequence model achieved an AUC of 97%±3.8, a sensitivity of 94%±12.4 and a specificity of 89%±9.0. The Boruta-based multi-sequence model achieved an AUC of 97%±3.7, a sensitivity of 95%±10.5 and a specificity of 87%±9.0.

CONCLUSION: The radiomics-based machine learning model can provide a promising tool to help distinguish fibro-adipose vascular anomaly from common venous malformations.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Dong, Gong, Liu, et al. Radiomics-based machine learning approach in differentiating fibro-adipose vascular anomaly from venous malformation. Pediatr Radiol. 2022. PMID: 36271054. doi:10.1007/s00247-022-05520-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。