文献速递神经骨肌MR

深度学习重建高分辨率三维颈椎MRI评估椎间孔狭窄

Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation.
PubMed 文献 · Skeletal Radiol · 2022-10-21

三维序列对椎间孔狭窄的观察者间一致性达「优秀」(k=0.81),优于二维(k=0.76),中央椎管狭窄两者均优秀,且三维运动伪影更少、扫描时间更短。

要点

  • 深度学习重建三维MRI对椎间孔狭窄的观察者间一致性达优秀,至少不劣于二维。
  • 三维序列运动伪影更少,平均扫描时间7.3分钟,较二维10.8分钟缩短。
  • 中央椎管狭窄评估两者一致性均优秀,三维可替代二维用于常规评估。

核心结论

  • 深度学习重建三维MRI对椎间孔和中央椎管狭窄提供「优秀」的观察者间一致性,至少等效于标准二维成像,且运动伪影更少并节省扫描时间。

研究设计与样本

  • 三位放射科医生回顾性评估运动伪影对临床评估的限制程度及每个层面的椎间孔和中央椎管狭窄,采用加权Fleiss kappa分析观察者间一致性,Wilcoxon符号秩检验比较二维与三维序列。

关键影像表现/征象

  • 三维序列感知到的运动伪影少于二维序列(p≤0.001-0.036)。
  • 二维序列平均总扫描时间10.8分钟,三维序列7.3分钟。

诊断标准与关键数值

  • 椎间孔狭窄观察者间一致性:二维序列k=0.76(「充分」),三维序列k=0.81(「优秀」)。
  • 中央椎管狭窄观察者间一致性:二维序列k=0.85、三维序列k=0.83,均为「优秀」。

临床应用与阅片要点

  • 三维深度学习重建序列可作为常规颈椎MRI评估椎间孔狭窄的替代方案,观察者间一致性更高且扫描更快。
  • 阅片时注意三维序列运动伪影更少,有助于提高椎间孔狭窄评估的可重复性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare standard-of-care two-dimensional MRI acquisitions of the cervical spine with those from a single three-dimensional MRI acquisition, reconstructed using a deep-learning-based reconstruction algorithm. We hypothesized that the improved image quality provided by deep-learning-based reconstruction would result in improved inter-rater agreement for cervical spine foraminal stenosis compared to conventional two-dimensional acquisitions.

MATERIALS AND METHODS: Forty-one patients underwent routine cervical spine MRI with a conventional protocol comprising two-dimensional T2-weighted fast spin echo scans (2 axial planes, 1 sagittal plane), and an isotropic-resolution three-dimensional T2-weighted fast spin echo scan reconstructed over a 4-h time window with a deep-learning-based reconstruction algorithm. Three radiologists retrospectively assessed images for the degree to which motion artifact limited clinical assessment, and foraminal and central stenosis at each level. Inter-rater agreement was analyzed with weighted Fleiss's kappa (k) and comparisons between two-dimensional and three-dimensional sequences were performed with Wilcoxon signed-rank test.

RESULTS: Inter-rater agreement for foraminal stenosis was "substantial" for two-dimensional sequences (k = 0.76) and "excellent" for the three-dimensional sequence (k = 0.81). Agreement was "excellent" for both sequences (k = 0.85 and 0.83) for central stenosis. The three-dimensional sequence had less perceptible motion artifact (p ≤ 0.001-0.036). Mean total scan time was 10.8 min for the two-dimensional sequences, and 7.3 min for the three-dimensional sequence.

CONCLUSION: Three-dimensional MRI reconstructed with a deep-learning-based algorithm provided "excellent" inter-observer agreement for foraminal and central stenosis, which was at least equivalent to standard-of-care two-dimensional imaging. Three-dimensional MRI with deep-learning-based reconstruction was less prone to motion artifact, with overall scan time savings.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Jardon, Tan, Chazen, et al. Deep-learning-reconstructed high-resolution 3D cervical spine MRI for foraminal stenosis evaluation. Skeletal Radiol. 2022. PMID: 36269331. doi:10.1007/s00256-022-04211-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。