文献速递乳腺MR

深度学习约束压缩感知加速3D高分辨率T2加权乳腺MRI:与常规T2加权序列在3.0T上的比较

Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T.
PubMed 文献 · Eur J Radiol · 2022-10-17

结果显示3D CS和AI-CS在病灶清晰度、形态、结构细节、整体图像质量、诊断信息及乳腺组织勾勒方面均显著优于常规T2WI(P<0.001),AI-CS 3D T2WI的对比噪声比显著高于常规T2WI,肿瘤体积与DCE无显著差异。结论认为AI-CS可实现各向同性3D T2WI并保持图像质量和诊断价值。

要点

  • AI-CS 3D T2WI在病灶清晰度、形态和结构细节上显著优于常规2D T2WI(P<0.001)。
  • AI-CS 3D T2WI的对比噪声比显著高于常规T2WI,但常规T2WI信噪比显著更高。
  • AI-CS 3D T2WI测得的肿瘤体积与DCE无显著差异,最大径与DCE及常规T2WI均无显著差异。

关键影像表现/征象

  • 3D CS和AI-CS在病灶清晰度和形态、结构细节、整体图像质量、乳腺病灶诊断信息及乳腺组织勾勒方面均显著优于常规T2WI(P<0.001)。
  • 常规T2WI的信噪比显著高于3D T2WI序列。
  • AI-CS 3D T2WI的对比噪声比显著高于常规T2WI序列。

诊断标准与关键数值

  • 图像质量采用5分制评分:1分表示不可评估质量,5分表示优秀质量。
  • 肿瘤体积比较:DCE(8.08 ± 16.51)与AI-CS 3D T2WI(8.25 ± 16.29)之间无显著差异。
  • 肿瘤最大径在DCE、AI-CS 3D T2WI和常规T2WI序列之间无显著差异。

临床应用与阅片要点

  • AI-CS 3D T2WI可作为常规T2WI的替代序列,提供各向同性高分辨率图像并保持诊断信息。
  • 阅片时注意AI-CS 3D T2WI上病灶呈稍高信号,肿瘤体积和最大径与DCE及常规T2WI无显著差异,可用于病灶测量。
  • 常规T2WI信噪比更高,但AI-CS 3D T2WI对比噪声比更优,需结合序列特点综合评估。

局限性

  • 未报告阅片者间一致性或盲法设计细节。
  • 未报告AI-CS 3D T2WI的扫描时间或加速因子。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the feasibility of isotropic 3D high-resolution T2-weighted imaging (T2WI) MRI sequences and compare the images reconstructed by integrating artificial intelligence-compressed sensing (AI-CS), compressed sensing (CS), and conventional 2D T2WI sequences for quality.

MATERIALS AND METHODS: Fifty-two female patients (ages: 26-80 years) with suspected breast cancer were enrolled. They underwent breast MRI examinations using three sequences: conventional T2WI, CS 3D T2WI, and AI-CS 3D T2WI. Image quality, signal-to-noise ratio (SNR), contrast-to-noise ratio, tumor volume, and maximal tumor diameter were compared using the Friedman test. Image quality was scored on a 5-point scale, with 1 indicating nonassessable quality and 5 indicating excellent quality. Tumor volume and maximal tumor diameter were compared based on AI-CS 3D T2WI (slightly high signal), conventional T2WI, and dynamic contrast-enhanced (DCE) sequences.

RESULTS: All three T2WI were successfully performed in all patients. 3D CS and AI-CS were significantly better than conventional T2WI in terms of lesion conspicuity and morphology, structural details, overall image quality, diagnostic information for breast lesions, and breast tissue delineation (P < 0.001). The SNR of conventional T2WI was significantly higher for 3D T2WI sequences. The contrast-to-noise ratio was significantly higher for AI-CS 3D T2WI than for conventional T2WI sequence. There was no significant difference in tumor volume between DCE (8.08 ± 16.51) and AI-CS 3D T2WI (8.25 ± 16.29) sequences and no significant differences in tumor diameter among DCE, AI-CS 3D T2WI, and conventional T2WI sequences.

CONCLUSION: Isotropic-resolution 3D T2WI sequences can be acquired using AI-CS while maintaining image quality and diagnostic value, which may pave the way for isotropic 3D high-resolution T2WI for clinical application.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yang, Pan, Zhu, et al. Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T. Eur J Radiol. 2022. PMID: 36270194. doi:10.1016/j.ejrad.2022.110562

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。