文献速递泌尿生殖骨肌MR

压缩感知各向同性3D T1 Dixon MRI评估前列腺癌骨转移的可行性

Evaluating prostate cancer bone metastasis using accelerated whole-body isotropic 3D T1-weighted Dixon MRI with compressed SENSE: a feasibility study.
PubMed 文献 · Eur Radiol · 2022-10-21

CSI-T1W-Dixon在轴位和冠状位伪影更少、部分CNR更优,且单用T1序列时病灶水平敏感度更高(82.7% vs 53.8%,P=0.03),患者水平诊断能力无差异。结论认为CSI-T1W-Dixon可替代CMP-T1W-Dixon用于临床评估骨转移。

要点

  • CSI-T1W-Dixon图像伪影更少,脂肪图CNR更优,扫描时间节省67%。
  • 单用T1序列时CSI-T1W-Dixon病灶检出敏感度显著高于CMP-T1W-Dixon。
  • 联合STIR和DWI后两种方法患者水平诊断能力无差异。
英文原文(摘要)· 点击展开

OBJECTIVES: The study aimed to assess the efficiency of whole-body high-resolution compressed sensing-sensitivity encoding isotropic T1-Weighted Dixon (CSI-T1W-Dixon) scans in evaluating bone metastasis.

METHODS: Forty-five high-risk prostate cancer patients with bone metastases were enrolled prospectively and underwent whole-body MRI sequences, which included the following: pre- and post-contrast CSI-T1W-Dixon and conventional multi-planar T1-Weighted Dixon (CMP-T1W-Dixon) (coronal, sagittal, and axial scans), short tau inversion recovery (STIR), and DWI. Comparison between the CMP-T1W-Dixon and CSI-T1W-Dixon images was done for the subjective image quality, the quantitative contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR). Furthermore, the diagnostic performance based on per-lesion and per-patient basis utilizing non-contrast T1-weighted (T1)/T1+ contrasted T1-weighted (T1C)/T1 + T1C + STIR + DWI sequences was compared between the CSI-T1W-Dixon and CMP-T1W-Dixon methods using reference standards (combining biopsy data and 6-month imaging follow-up).

RESULT: The CSI-T1W-Dixon images produced fewer image artifacts in the axial and coronal planes compared to the CMP-T1W-Dixon images. Also, the CSI-T1W-Dixon images provided better a CNR in fat-only images of all three planes and water-only images of the axial plane (p < 0.05). The CSI-T1W-Dixon showed a higher sensitivity than the CMP-T1W-Dixon techniques in analyzing T1-only images on a per-lesion basis (82.7% vs. 53.8% for sensitivity, p = 0.03). On a per-patient basis, no difference was found in the diagnostic capacity between the CSI-T1W-Dixon and CMP-T1W-Dixon sequences either alone or in combinations (p = 0.57-1).

CONCLUSION: High-resolution CSI-T1W-Dixon with higher image quality and diagnostic capacity can replace the CMP-T1W-Dixon method in evaluating bone metastasis in clinical practice.

KEY POINTS: • Compressed sensing isotropic acquisition for 3D T1-weighted Dixon images can improve the image quality with fewer artifacts compared to the anisotropic multiplanar acquisition. • Compressed sensing isotropic acquisition can save 67% of scanning time compared to anisotropic multiplanar acquisition. • Compressed sensing isotropic 3D T1-weighted Dixon images can offer better diagnostic performance with higher sensitivity compared to anisotropic multiplanar images.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Liao, Liu, Ming, et al. Evaluating prostate cancer bone metastasis using accelerated whole-body isotropic 3D T1-weighted Dixon MRI with compressed SENSE: a feasibility study. Eur Radiol. 2022. PMID: 36269371. doi:10.1007/s00330-022-09181-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。