文献速递甲状腺与浅表儿科影像US

儿童及年轻成人甲状腺结节超声:放射科医师印象、ACR TI-RADS与深度学习算法的诊断性能比较

Thyroid Nodules on Ultrasound in Children and Young Adults: Comparison of Diagnostic Performance of Radiologists' Impressions, ACR TI-RADS, and a Deep Learning Algorithm.
PubMed 文献 · AJR Am J Roentgenol · 2022-10-19

该回顾性研究纳入139例≤21岁、有明确病理结果的甲状腺结节患者,比较放射科医师整体印象、ACR TI-RADS和深度学习算法的诊断性能。结果显示ACR TI-RADS和深度学习算法敏感性更高但特异性更低;深度学习算法敏感性类似ACR TI-RADS但特异性更低;ACR TI-RADS观察者间一致性更高。

要点

  • ACR TI-RADS在儿童甲状腺结节中敏感性高(平均85.1%),但特异性仅约50.6%。
  • 深度学习算法敏感性87.5%,特异性36.1%,可作为辅助分诊工具。
  • 放射科医师整体印象敏感性变异大(32.1%-75.0%),一致性较低(kappa 0.227-0.472)。

局限性

  • 单中心回顾性研究,样本量有限(139例)。
  • 深度学习算法为既往开发,未在儿童人群中重新训练或验证。
  • 仅纳入有病理结果的患者,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. In current clinical practice, thyroid nodules in children are generally evaluated on the basis of radiologists' overall impressions of ultrasound images. OBJECTIVE. The purpose of this article is to compare the diagnostic performance of radiologists' overall impression, the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS), and a deep learning algorithm in differentiating benign and malignant thyroid nodules on ultrasound in children and young adults. METHODS. This retrospective study included 139 patients (median age 17.5 years; 119 female patients, 20 male patients) evaluated from January 1, 2004, to September 18, 2020, who were 21 years old and younger with a thyroid nodule on ultrasound with definitive pathologic results from fine-needle aspiration and/or surgical excision to serve as the reference standard. A single nodule per patient was selected, and one transverse and one longitudinal image each of the nodules were extracted for further evaluation. Three radiologists independently characterized nodules on the basis of their overall impression (benign vs malignant) and ACR TI-RADS. A previously developed deep learning algorithm determined for each nodule a likelihood of malignancy, which was used to derive a risk level. Sensitivities and specificities for malignancy were calculated. Agreement was assessed using Cohen kappa coefficients. RESULTS. For radiologists' overall impression, sensitivity ranged from 32.1% to 75.0% (mean, 58.3%; 95% CI, 49.2-67.3%), and specificity ranged from 63.8% to 93.9% (mean, 79.9%; 95% CI, 73.8-85.7%). For ACR TI-RADS, sensitivity ranged from 82.1% to 87.5% (mean, 85.1%; 95% CI, 77.3-92.1%), and specificity ranged from 47.0% to 54.2% (mean, 50.6%; 95% CI, 41.4-59.8%). The deep learning algorithm had a sensitivity of 87.5% (95% CI, 78.3-95.5%) and specificity of 36.1% (95% CI, 25.6-46.8%). Interobserver agreement among pairwise combinations of readers, expressed as kappa, for overall impression was 0.227-0.472 and for ACR TI-RADS was 0.597-0.643. CONCLUSION. Both ACR TI-RADS and the deep learning algorithm had higher sensitivity albeit lower specificity compared with overall impressions. The deep learning algorithm had similar sensitivity but lower specificity than ACR TI-RADS. Interobserver agreement was higher for ACR TI-RADS than for overall impressions. CLINICAL IMPACT. ACR TI-RADS and the deep learning algorithm may serve as potential alternative strategies for guiding decisions to perform fine-needle aspiration of thyroid nodules in children.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Yang, Page, Wagner, et al. Thyroid Nodules on Ultrasound in Children and Young Adults: Comparison of Diagnostic Performance of Radiologists' Impressions, ACR TI-RADS, and a Deep Learning Algorithm. AJR Am J Roentgenol. 2022. PMID: 36259591. doi:10.2214/AJR.22.28231

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。