腹部盆腔CT图像质量:深度学习重建0.5mm薄层图像评估
回顾性纳入50例腹部盆腔CT,比较0.5mm深度学习重建(DLR)与0.5mm及3.0mm混合迭代重建(HIR)的图像质量。结果显示DLR在噪声和整体图像质量上明显优于薄层及厚层HIR,且不增加伪影,提示临床解读时或可仅用薄层DLR替代现有薄层与厚层HIR。
要点
- 0.5mm DLR较0.5mm HIR在噪声和整体图像质量上获明确偏好(中位评分2),锐利度和自然外观获轻微偏好(评分1)。
- 0.5mm DLR较3.0mm HIR在噪声、整体图像质量、锐利度、自然外观四项均获轻微偏好(中位评分1)。
- 0.5mm DLR较0.5mm HIR噪声平均降低12.8 HU,较3.0mm HIR降低4.4 HU(均p<.001)。
局限性
- 原文未明确报告研究是否为单中心。
- 仅评估图像质量和噪声,未评估诊断性能。
- 样本量50例,为回顾性设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND. Because thick-section images (typically 3-5 mm) have low image noise, radiologists typically use them to perform clinical interpretation, although they may additionally refer to thin-section images (typically 0.5-0.625 mm) for problem solving. Deep learning reconstruction (DLR) can yield thin-section images with low noise. OBJECTIVE. The purpose of this study is to compare abdominopelvic CT image quality between thin-section DLR images and thin- and thick-section hybrid iterative reconstruction (HIR) images. METHODS. This retrospective study included 50 patients (31 men and 19 women; median age, 64 years) who underwent abdominopelvic CT between June 15, 2020, and July 29, 2020. Images were reconstructed at 0.5-mm section using DLR and at 0.5-mm and 3.0-mm sections using HIR. Five radiologists independently performed pairwise comparisons (0.5-mm DLR and either 0.5-mm or 3.0-mm HIR) and recorded the preferred image for subjective image quality measures (scale, -2 to 2). The pooled scores of readers were compared with a score of 0 (denoting no preference). Image noise was quantified using the SD of ROIs on regions of homogeneous liver. RESULTS. For comparison of 0.5-mm DLR images and 0.5-mm HIR images, the median pooled score was 2 (indicating a definite preference for DLR) for noise and overall image quality and 1 (denoting a slight preference for DLR) for sharpness and natural appearance. For comparison of 0.5-mm DLR and 3.0-mm HIR, the median pooled score was 1 for the four previously mentioned measures. These assessments were all significantly different (p < .001) from 0. For artifacts, the median pooled score for both comparisons was 0, which was not significant for comparison with 3.0-mm HIR (p = .03) but was significant for comparison with 0.5-mm HIR (p < .001) due to imbalance in scores of 1 (n = 28) and -1 (slight preference for HIR, n = 1). Noise for 0.5-mm DLR was lower by mean differences of 12.8 HU compared with 0.5-mm HIR and 4.4 HU compared with 3.0-mm HIR (both p < .001). CONCLUSION. Thin-section DLR improves subjective image quality and reduces image noise compared with currently used thin- and thick-section HIR, without causing additional artifacts. CLINICAL IMPACT. Although further diagnostic performance studies are warranted, the findings suggest the possibility of replacing current use of both thin- and thick-section HIR with the use of thin-section DLR only during clinical interpretations.
引用
- Oostveen, Smit, Dekker, et al. Abdominopelvic CT Image Quality: Evaluation of Thin (0.5-mm) Slices Using Deep Learning Reconstruction. AJR Am J Roentgenol. 2022. PMID: 36259592. doi:10.2214/AJR.22.28319
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。